Mr. Bernard P. Orlan November 25, 2002
Wipe Samples for Dioxirs Page 2
P. S. 124 Manhattan ATC Project No. 15-19125-0350
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer
were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by
multiplying by an established equivalency factor. This provides a single value (in nanogi'ams)
for the analytical results for each sample. A copy of the laboratory analysis report is attached.
The results are shown in the following table.
DIOXIN WIPE SAMPLE RESULTS
2, 3, 7, 8 TC DD EQUIVALENTS - Nanograms per square meter (ng/m^)
September 12, 2002
LOCATIOl'f /SAMPLE ID DIOXIN CONCENTRATION
Lobby-M lin Entrance / DX-1 0.00
2nd Floor Hallway by Room 222 / 0.000035
_________ DX-2____________
y^TioorlJillway by Room 307 / 0.00
DX-3
Blank/DX-4 0.00
The New York State Department of Health (NYSDOH) established guidelines for dioxm for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m2).
The concentrations on indoor surfaces ranged from 0.00 to 0.000035 nanograms per square
meter (ng/m^). The levels found in all of these samples are below the NYSDOH guideline of
25 ng/m2.
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples
was deposited. Dioxin samples were not collected from these locations prior to these samples
therefore a background sample is not available for comparison purposes.
It is our pleasure to p -ovide these indoor environmental services to the NYC Department of
Education. If you hav; any questions about this report, please call (212) 353-8280, e?itension
212.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Div sion
Attachment