Mr. Bernard P. Orlan November 25, 2002 Wipe Samples for Dioxirs Page 2 P. S. 124 Manhattan ATC Project No. 15-19125-0350

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value (in nanogi'ams) for the analytical results for each sample. A copy of the laboratory analysis report is attached. The results are shown in the following table.

DIOXIN WIPE SAMPLE RESULTS 2, 3, 7, 8 TC DD EQUIVALENTS - Nanograms per square meter (ng/m^) September 12, 2002 LOCATIOl'f /SAMPLE ID DIOXIN CONCENTRATION

Lobby-M lin Entrance / DX-1 0.00

2nd Floor Hallway by Room 222 / 0.000035 _________ DX-2____________ y^TioorlJillway by Room 307 / 0.00 DX-3 Blank/DX-4 0.00

The New York State Department of Health (NYSDOH) established guidelines for dioxm for the re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m2).

The concentrations on indoor surfaces ranged from 0.00 to 0.000035 nanograms per square meter (ng/m^). The levels found in all of these samples are below the NYSDOH guideline of 25 ng/m2.

It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples was deposited. Dioxin samples were not collected from these locations prior to these samples therefore a background sample is not available for comparison purposes.

It is our pleasure to p -ovide these indoor environmental services to the NYC Department of Education. If you hav; any questions about this report, please call (212) 353-8280, e?itension 212.

Sincerely, ATC Associates, Inc.

James R. Cohn, CIH, CSP Regional Manager Industrial Hygiene Div sion

Attachment

CITY_21MC100_003021096

NYC-WTC_000353322

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353322Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Dioxin wipe sample report, P.S. IM, Nov 2002

NYC-WTC_000196715

Report detailing results of wipe samples collected to evaluate polychlorinated dibenzo-p-dioxins and dibenzofurans contamination at a school.

Similar indexed content

Compare copies and versions →