NYC 9/11 Public Portal Document
•w
...— ...............................
psc 610-921-9667 r -'
Jun 17 02 10:16a
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
PSC
SiRWiS •EPAAIVtAP 101262-0 • NY DOHJNELAC10903 •NJDEP PA020
• AIHA ACCREDITATION NO. 100438 •PADEP06-3B3 •CT DPH Pl+0238
•NCDENR599
Analytical Results
for
ATC Associates
WorkOrder: R02060251
Client Reference: 19)25-0297 Metals
Analyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst
(ug) i (mg/m^) I (ppm) (ue)
Client ID; ATC-0530-89M-M5 Lab ID: -OSA Date Sampled: 5/30/2002 Matrix: Filter Air Vol.(L): NA
Aluminum <1.00 1 N7300 MCE 06/14/2002 DS
Cadmium <0.200 0.2 N7300 MCE 06/14/2002 DS
Chromium ^0 hAfi 0.2 N730O MCE 06/14/2002 DS
Cobalt <0.100 0.1 N7300 MCE 06/14/2002 DS
Copper <0.200 0.2 N7300 MCE 06/14/2002 DS
Iron <2.00 2 N7300 MCE 06/14/2002 DS
Lead <0.300 0.3 N7300 MCE 06/14/2002 DS
Magnesium <1.30 1.3 N7300 MCE 06/14/2002 DS
Manganese <0.300 0.3 N7300 MCE 06/14/2002 DS
Molybdenum <1.00 1 N7300 MCE 06/14/2002 DS
Nickel <0.200 0.2 N7300 MCE 06/14/2002 DS
Zinc <0.500 0.5 N7300 MCE 06/14/2002 DS
Client ID: A'rC-0530-89M-M6 Lab ID: -06A Date Sampled: 5/30/2002 Matrix: Filter Air Vol.(L): N.A
Aluminum <1.00 1 N7300 MCE 06/14/2002 DS
Cadmium <0.200 0.2 N7300 MCE 06/14/2002 DS
Chromium 0.322 0.2 N7300 MCE 06/14/2002 DS
Cobalt <0.100 0.1 N7300 MCE 06/14/2002 DS
Copper <0.200 0.2 N7300 MCE 06/14/2002 DS
Iron <2.00 2 N7300 MCE 06/14/2002 DS
Lead <0.300 0.3 N7300 MCE 06/14/2002 DS
Magnesium <1.30 1.3 N73O0 MCE 06/14/2002 DS
Manganese <0.300 0.3 N7300 MCE 06/14/2002 DS
Molybdenum <1.00 1 N730O MCE 06/14/2002 DS
Nickel <0.200 0.2 N730O MCE 06/14/2002 DS
Zinc <0.500 0.5 N730O MCE 06/14/2002 DS
(a) Analysis indicates possible breakthrouglt; back section result is greater than 0% of the front section result.
General Notes:
<; I.ess than the indicated limit of detection (LOD).
—; Information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
Page 3 of 3
CITY_21MC1OO_OO3O18677
NYC-VVTC_000351677
OCR can misread numbers and units. Confirm readings against the page image before using them.