NYC-WTC_000259575
Chain-of-custody form for industrial hygiene/ environmental testing (ATC).
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗Analytical report for ATC analytical services; received/reported dates.
NYC-WTC_000351528–000351533OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Jan 22 02 09:10a PSC Analytical Services 6109219667 P-2
1 page 2 of 6 21 JAN02_1510 J3_H7Z47_RFR
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING . EPA/NVIAP 101262-0 - NV DOH 10903 • NJ DEP 77078 . AIHA ACCREDITATION NO, 100439 - PA DER 06-353 - CT DPH PH-Ozaa . NC DENK 599
Projeex: 209336 result UNITS CONCENTRATION UNITS METHog AIC-On3-M833-VOC2 UlrUi Lab Sample: 1476119 - conxinuad '
Chloroform < 0.020 mg/sample < 0-034 ppm 1003 Methyl chloroform < 0.020 mg/sample < 0.031 ppm 1003 total other A Hydrocarbons < 0.020 mg/sample < 0.047 ppm 1500 Benzene < 0.020 mg/sample <= 0.052 ppm 1501 1,2-Dichloroethane 0,128 mg/sample 0.264 ppm 1003 Trichloroethylene 0-020 mg/sample < 0.031 ppm 1022 Toluene < 0.020 mg/sample < 0.044 ppm 1501 PCE (Tetrachloroethene) < 0-020 mg/sampla < 0.025 ppm 1003 chlorobenzene < 0.D2O mg/sample < 0.036 ppm 1003 Ethylbenzene < 0.020 mg/sample < 0.039 ppm 1501 Styrene < 0.020 mg/sample < 0.039 ppm 11501 Cumene (Isopropylbenzene) < 0.020 mg/sample < 0.034 ppm 1501 Xylenes, Total < 0,020 mg/sample < 0.03B ppm 1501 total other B Hydrocartions 0.023 mg/sample 0.064 ppm 1501
ATC-0113-M633-VOC3 3 iboz k<l//lA/sM Air Volume; 120 L Lab Sample: 1476120
Pentane < 0.020 mg/samplB c 0.056 ppm 1500 Acetone < 0.020 mg/sample e 0.070 ppm 1300 Methylene chloride < 0.020 mg/sample < 0.D4B ppm 1005 Hexane 0.050 mg/sample 0 . IIS ppm 1500 Chloroform c 0.020 mg/sample < 0.034 ppm 1003 Methyl chloroform < 0.020 mg/sample c 0.031 ppm 1003 total other A Hydrocarbons < 0.020 mg/sample < 0.047 ppm 1500 Benzene < 0.020 mg/sample < 0.052 ppm 1501 1,2-DichloroBthane < 0.Q2Q mg/sample < 0-041 ppm 1003 Trichloroethylene < 0.020 mg/sampte < 0,031 ppm 1 022 Toluene < 0.020 mg/sample < 0 - 044 ppm 1601 PCE (Tetrachloroethene) 0.020 mg/sample < 0-02-5 ppm 1003 Chlorobenzene < 0.020 mg/sample < 0.036 ppm 1003 Ethylbenzene < 0.020 mg/sample < 0,03(3 ppm 1501 Styrene < 0.020 ma/sample < 0.039 ppm 15C1 Cumene (Isopropylbenzene) < 0.020 mg/samp1e < 0.034 ppm 1501 Xylenes. Total < 0.020 mg/sample < Q.038 ppm 1501 total other B Hydrocarbons < 0.020 mg/sample < 0.044 ppm 1501
ATC-On3-M833-VOC4 Air Volume: 120 L Lab Sample; 1476121
i Pentane < 0,020 mg/samp!e < 0 .05E ppm 1500 I Acetone <■0.020 mg/sampls < 0.070 ppm 1300
4413 POTTSVILLE PIKE, READING. PENNSYLVANIA 1S6D5 610-B21-8833 FAX 61 0-921-9667
CITY_21MC100_003018474
NYC-WTC_000351529
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000259575
Chain-of-custody form for industrial hygiene/ environmental testing (ATC).
7 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256900
Analytical report for industrial hygiene samples, project 19125-0291.
7 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000311045
Industrial hygiene analytical report for ATC 209192 with received/reported dates.
7 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000376852
Analytical report for hydrocarbons under ATC WorkOrder 19125-0290.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000297613
ATC analytical results for hydrocarbons in school sample set, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238061
Cover page for an industrial hygiene and environmental testing analytical report received in December 2001 and reported January 2002.
7 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401282
Analytical report for hydrocarbons, sampled 12/20/01 at ATC High School
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401286
Analytical report for hydrocarbon sampling 12/26/01–01/02/02 at ATC High School.
7 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238057
Cover page for an industrial hygiene and environmental testing analytical report received in December 2001.
7 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312636
Analytical report for ATC project, samples collected 12-20-01.
7 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401292
Analytical report for hydrocarbons A&B, sampled 01-03-02 at the school.
7 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238068
Cover page for an industrial hygiene and environmental testing analytical report received in January 2002.
7 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000259575
Chain-of-custody form for industrial hygiene/ environmental testing (ATC).
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256900
Analytical report for industrial hygiene samples, project 19125-0291.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000259575
Chain-of-custody form for industrial hygiene/ environmental testing (ATC).
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256900
Analytical report for industrial hygiene samples, project 19125-0291.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000401292
Analytical report for hydrocarbons A&B, sampled 01-03-02 at the school.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000312560
Analytical report for ATC samples; Received Nov 15, Reported Nov 20, 2001.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000259575
Chain-of-custody form for industrial hygiene/ environmental testing (ATC).
Similar indexed content
NYC-WTC_000256900
Analytical report for industrial hygiene samples, project 19125-0291.
Similar indexed content
NYC-WTC_000311045
Industrial hygiene analytical report for ATC 209192 with received/reported dates.
Similar indexed content
NYC-WTC_000376852
Analytical report for hydrocarbons under ATC WorkOrder 19125-0290.
Similar indexed content
NYC-WTC_000297613
ATC analytical results for hydrocarbons in school sample set, Jan 2002.
Similar indexed content