Real-time air monitoring report, BOE, Jun 2002

Machine-extracted title · confidence 42%

ATC reports real-time respirable particulates monitoring conducted Jun 7, 2002 for NYC Board of Education.

NYC-WTC_000351447–000351448
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan June 7, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATCProiectNo^l5J^125-0314 REAL-TIME SAMPLING RESULTS

Twenty-seven (24) indoor and twenty-nine (29) outdoor respirable particulates measurements* were collected from twenty-nine (29) School locations in Manhattan, ranging from West 11^^ Street to East 33rd Street. The measurements were made from 7:34 A.M. to 16:37 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 14 pg/m^ to 23 pg/m^ with an average of 19 pg/m^. The indoor concentrations ranged from 9 pg/m^ to 19 pg/m^ with an average of 17 pg/m^. Twenty-four of the of the indoor readings and all of the outdoor readings bellow the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. All of the indoor and outdoor readings were bellow the USEPA recommended guideline for children and sensitive individuals of 40 pg/m^.

These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION Based on our measurements, twenty-four (24) of the indoor and all of the outdoor readings were bellow the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. All of the indoor and all of the outdoor measurements were bellow the USEPA recommended guideline for children and sensitive individuals of 40 pg/m^.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call‘(212) 353-8280, extension 212 or 290.

Sincerely, Reviewed by: A TC ASSOCIA TES INC.

Prasad Doddapaneni James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division Attachment

CITY_21MC100_003018246

NYC-WTC_000351448

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000351448Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →