NYC 9/11 Public Portal Document
Pace Analytical Services. Inc.
1700 Elm Street-Suite 200
Minneapolis, MN 55414
tm
^ace Analytical_________ Method 8290 Analysis Results
Tel; 612-607’1700
Fax- 612- 607-6444
Client - ATC ASSOCIATES
Client’s Sample ID ATC-0823-2M-DX-2
Lab Sample ID 103800439
Filename F20928A_12
Injected By JAS
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/23/2002
ICAL Date 09/26/2002 Received 08/24/2002
CCal Filenamefs) F20927B_16 & F20928A_16 Extracted 09/21/2002
Method Blank ID BLANK-2193 Analyzed 09/28/2002 22:08
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7,8-TCDF ND -- 0.0034 A 2,3,7,8-TCDF-13C 2.00 71
Total TCDF ND — 0.0020 2.3,7,8-TCDD-13C 2.00 71
1,2,3,7,8-PeCDF-13C 2.00 75
2,3.7,8-TCDD ND 0.0034 A 2,3,4.7,8-PeCDF-13C 2.00 73
Total TCDD ND 0.0020 1,2,3,7.8-PeCDD-13C 2.00 77
1,2,3,4,7,8-HxCDF-13C 2.00 89
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 85
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6.7,8-HxCDF-13C 2.00 80
Total PeCDF ND 0.0100 1,2,3,7.8.9-HxCDF-13C 2.00 71
1,2.3,4,7,8-HxCDD-13C 2.00 112
1,2,3.7.8-PeCDD ND 0.0100 1,2,3,6,7.8-HxCDD-13C 2.00 78
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 66
1,2,3,4,7,8,9-HpCDF-13C 2.00 49
1,2,3,4,7.8-HxCDF ND 0,0100 1.2,3,4,6.7,8-HpCDD-13C 2.00 57
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 60 ‘
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3.4-TCDD-13C 2,00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3.4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 71
1,2,3,6.7.8-HxCDD ND 0.0100
1,2,3.7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,6,7.8-HpCDF 0.033 0.0100 J Total 2,3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.0027 ng/m2
Total HpCDF 0.068 0.0100 J (Using ITE Factors)
1,2,3.4,6.7,8-HpCDD 0.099 0.0100
Total HpCDD 0.340 0.0100
OCDF 0.100 0.0200
OCDD 1.300 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7.8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
8 = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target rang© NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 1061758
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc,
CITY_21MC100_003017737