NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
2 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Groundwater sample results table for PS 65 site.
NYC-WTC_000350679–000350684OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
I Page 2 of 6
TABLE 2
I PRELIMINARY GROUNDWATER SAMPLE RESULTS FORMER OZONE INDUSTRIES (PUBLIC SCHOOL 65) JULY 2002 I Location ID GP-11 GP-12 GP-12 GP-12 GP-13 Sample ID GP-11-75 GP-12-4<I GP-12-SS GP-12-75 GP-13-40
I Matrix Depth Interval (ft) Date Sampled Groundwater 73.5-75.0 07/11/02 Groundwater 38.5-40.0 07/11/02 Groundwater 53.5-55.0 07/11/02 Groundwater 73.5-75.0 07/11/02 Groundwater 38.5-40.0 07/12/02 Parameter Units Criteria*
Volatile Organic Compounds
I 1,1,1 -Trichloroethane
1,1,2-Trichlora-1,2,2-trifluoroethane UG/L
UG/L 5
5 0.3 J 3J 0.8 J 18
I 1,1,2-Trichloroethane
1,1-Dicliloroethane UG/L
UG/L 1
5 1 J 0.8 J 2J
3J
1,1-Dicliloroethene S
I 1,4-Dichlorobenzene UG/L
UG/L 3 2J
Methyl Ethyl Ketone (2-Butanone) 50 UG/L 2J
I Bromomethane
Chloroform UG/L 5
7 UG/L 0.7 J 0.8 J 0.7 J 0.5 J 0.5 J
I cis-1,2-Dichloroethena
Methyl tert-butyl ether UG/L
UG/L 5
10 2J 15
0.6 J 6J 2J 150
0.8 J Tetrachloroethene 5 UG/L 3J Toluene 5 UG/L 0.4 J 0.4 J 0.4 J 0.9 J trans-1,2-Dichloroethene 5
I Trichloroethene UG/L
UG/L 5 13 41 18 6J 0.3 J
2,400 D Xylene (total) 5
I UG/L 2J
I I •Criteria- NYSDEC TOGS (1.1.1), Ambient Water Quality Standards and Guidance Values and Groundwater Effluent Limitations. June 1998 (Includes 4/2000 Addendum). Class GA. Flags assigned during chemistry validation are shown.
c Concentration Exceeds Criteria.
J ’ The reported concentration is an estimated value. D - Result reported from a secondary dilution analysis.
I Made By:JJL 7/26/02_
Only Detected Results Reported. J:'.5«»4 01\db'proortmVPrDOnm.nW6 Pr1nt«J: 0Z/2W200Z11:Se:t9AM
I [LOODATEl BETWEEN*07/04/021 ANO «7/IS/tKi»ANOdSACOOq - N OR [SACODEj - TO' )AND [MATRIX] WG'AND [PRCCOOE] - VOA'AND IVOCIO|UKf’GW
CITY_2IMCl00_000914058 NYC-WTC_000350680
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
2 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350685
Groundwater sampling data table for Former Ozone site at PS 65.
1 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350665
Soil gas sampling results table for PS 65 related to former Ozone Industries.
2 shared non-person entities · 1 shared topics · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350692
Table of field QC samples for PS 65 groundwater study.
1 shared non-person entities · 1 shared topics · similarity 0.881
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281221
Analytical results table for dioxins/furans and related parameters from WTC water samples.
1 shared non-person entities · 1 shared topics · similarity 0.880
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454239
VOCs in water and air near World Trade Center; table of VOCs and sample IDs from WTC site.
2 shared non-person entities · 1 shared topics · similarity 0.879
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268759
Summary of analytical results with sample IDs and generic guidance notes.
1 shared topics · similarity 0.874
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000287898
Preliminary data report for World Trade Center sampling at PATH dewatering location.
1 shared non-person entities · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349144
Volatile organics results summary and LC/MS data for WTC samples.
2 shared non-person entities · 1 shared topics · similarity 0.872
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280288
Lab results for two water samples; 1.0 dilution; units ug/L; benzene and other volatiles listed.
1 shared non-person entities · 1 shared topics · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000387359
Analytical results overview for soil and water samples; data fields show contaminants and methods.
1 shared non-person entities · 1 shared topics · similarity 0.871
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000331105
Summary of analytical results for environmental samples; guidance and standards referenced for cleanup applicability.
1 shared non-person entities · 1 shared topics · similarity 0.870
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350685
Groundwater sampling data table for Former Ozone site at PS 65.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350685
Groundwater sampling data table for Former Ozone site at PS 65.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000350673
Groundwater sampling results table for PS 65 at Former Ozone Industries.
Similar indexed content
NYC-WTC_000350685
Groundwater sampling data table for Former Ozone site at PS 65.
Similar indexed content
NYC-WTC_000350665
Soil gas sampling results table for PS 65 related to former Ozone Industries.
Similar indexed content
NYC-WTC_000350692
Table of field QC samples for PS 65 groundwater study.
Similar indexed content
NYC-WTC_000281221
Analytical results table for dioxins/furans and related parameters from WTC water samples.
Similar indexed content