NYC-WTC_000349899
Asbestos analysis report for exterior/interior building areas at New Stuyvesant High School, June 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM analysis results with asbestos type and concentration for New Stuyvesant HS project.
NYC-WTC_000349728–000349730OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 6/12/02 9:00:00 PM N.Y.C. Board of Education ATC Group#: 8075 28-11 Queens Plaza North Analysis Date: 6/12/02 Long Island City, NY 11101 Fax: (212)475-4122 - . Phone: (212)477-8941 Project: New Stuyvesant H. .S., 345 Chambers St., NY , NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos ■ Area Non. Asbestos # Structures . Sensitivity Concentration ■ ■ Sample f^oluine Analyzed Asb Type(s) O.Sft-5 5/i '■ (S/cc) (S/mm^) (S/cc) Noles'
'2 1920.00 0.0450 0 NoneDetected 0 .0 0.0045 <22.24 ',<0.0045 80 75 -17 '
• 18 • .1920.00 ■.0.0450' . 0 NoneDetected 0 0 0.0045 <22.24 <0:0045 • . 8075 -IS ' , ■
19 1920.00 0.0450 0 NoneDetected 0 0 0.0045 <22.24 . <0.0045 8075 -19
• 20 • • . 1920.00 0.0450.. 0 None Detected. 0 O' 0.0045 ' <22.24 <0.0045 8075 -20
21 1920.00 0.0450 0 NoneDetected 0 0 0.0045 <22.24' <0.0045 8075 -21 '
ROMAN PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by: ' Approved by:
__________ ____ ;_________ / Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by .non-laboratory personnfekYhis lab is only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%. confidence limits and laboratory and analysis'-accuracy and precision) is available upon request
Accredited (or NVLAP PLM/TEM #101187-0, NY State ELAP #10879
Page 3 of 3
CITY_21MC100_003015194
NYC-WTC_000349730
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000349899
Asbestos analysis report for exterior/interior building areas at New Stuyvesant High School, June 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349764
Report covering TEM asbestos analysis for exterior/interior of building and fibers.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194714
Formal analytical report from ATC Associates detailing transmission electron microscopy results for asbestos fibers in air samples from a New York City Board of Education building.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299096
TEM asbestos analysis results for air samples at building exterior/interior areas.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380886
TEM asbestos analysis results for New Stuyvesant High School, Mar 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191749
Formal laboratory report from ATC Associates detailing TEM asbestos fiber analysis for a New York City Board of Education high school project.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410899
TEM analysis report for exterior/interior asbestos samples at New Stuyvesant HS, Mar 2002.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299271
TEM asbestos analysis results with concentrations and notes for building samples.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000299205
TEM asbestos analysis report for exterior/interior areas of New Stuyvesant High School.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300045
TEM analysis of air samples at New Stuyvesant High School, Apr 2002.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191415
ATC Associates report detailing exterior and interior asbestos fiber analysis by TEM microscopy for a New York City Board of Education high school project.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000190835
Comprehensive laboratory report from ATC Associates detailing exterior and interior building fiber analysis performed for the NYC Board of Education on April 28, 2002.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000349504
TEM asbestos analysis for building samples at New Stuyvesant HS; AHERA-compliant methodology.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398658
Asbestos TEM analysis report for New Stuyvesant High School, December 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000349812
TEM asbestos analysis results for air samples at New Stuyvesant High School exterior/interior.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000191749
Formal laboratory report from ATC Associates detailing TEM asbestos fiber analysis for a New York City Board of Education high school project.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000257266
TEM asbestos analysis detailed results for exterior/interior building areas at New Stuyvesant High School.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380556
TEM asbestos analysis of air samples at New Stuyvesant High School, exterior/interior areas, Mar 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Asbestos analysis report for exterior/interior building areas at New Stuyvesant High School, June 2002.
Similar indexed content
Report covering TEM asbestos analysis for exterior/interior of building and fibers.
Similar indexed content
NYC-WTC_000194714
Formal analytical report from ATC Associates detailing transmission electron microscopy results for asbestos fibers in air samples from a New York City Board of Education building.
Similar indexed content
TEM asbestos analysis results for air samples at building exterior/interior areas.
Similar indexed content
TEM asbestos analysis results for New Stuyvesant High School, Mar 2002.
Similar indexed content