TEM analysis data, New Stuyvesant HS, Jun 2002

Machine-extracted title · confidence 40%

Asbestos TEM analysis results for exterior/interior of New Stuyvesant HS; data transmitted 06/10/02.

NYC-WTC_000349702–000349704
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Attn; Mr. Bernard Orlan Received: 6/10/02 8:00:00 PM N.Y.C. Board of Education ATC Group #: 8036 28-11 Queens Plaza North Analysis Date: 6/10/02 Long Island-City,. • NY . 11101' Fax: ■(212)475-4122 . ' Phone:. (212) 477--8941 Project: Netv Stuyvesant H.’S., 345 Chambers St., NY , NY ■ ■ Exterior and Interior of.Building and Roof ,

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) ■ Analytical Asbestos Area Non Asbestos # Structures. • Sensitivity Concentration Sample Volume Analyzed Asb . Type(s). 0.5H-5 5^ (S/cc) (S/mm^) (S/cc) Notes ;

8 1928.00 0.0450 . 0 ' NoneDetected 0 0 0.0044 <22.24 <0.0044 8036 -8

9 1936.00 0.0450 , 0 NoneDetected O' 0 0.0044 <22.24 <0.0044 8036 -9

10 .- 1920.00 0.0450' .0 None Detected 0 0 0.0045 <22.24 • <0.0045 • 8036 -10

I! 1920.00 0.0450 '0 CHRYSOTILE 1 0 0.0045 22.24 0.0045 8036 -II

' ’2 1920.00. 0.0450 0 NoneDetected 0 0 0.0045 <22.24 <0.0045 8036 -12 ■ . : ■ . . . ■ ■ .

'5 . 1928.00 .0.0450 0 ' None Detected 0 0 0.0044 <22.24 <0.0044 8036 -13 ‘ ■

14 1928.00 .0.0450 0 NoneDetected 0 O' 0.0044 <22.24 <0.0044 8036 -14

• 15.; 1936.00 0.0450 ' 0 NoneDetected 0 0 0.0044 .<22.24 <0.0044 • 3036 -15

16 1944.00 0.0450 . 0 NoneDetected 0 0 0.0044 <22.24 <0.0044 8036 -!6

MICHAEL A. GORYCKI, Ph.D. ROMAN PEYSAKjyV . Analyzed by: Approved by:

: Disclaimer Ths laboratory is'not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. ThiCiafi is only responsible ’ for data reported in stmctures/mml This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency ol the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% .' ' confidence limits and laboratory and analysis' accuracy and precision) is available upon request.

■ Accredited lor NVLAP PLM/TEM #10.1187-0, NY State ELAP #10879

Page 2 of 3

CITY_21MC100_0 03015135

NYC-WTC_000349703

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000349703Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000349790

TEM asbestos results for air samples at New Stuyvesant High School exterior/interior.

Similar indexed content

NYC-WTC_000349764

Report covering TEM asbestos analysis for exterior/interior of building and fibers.

Similar indexed content

NYC-WTC_000349638

Asbestos TEM analysis results for exterior/interior of building and fiber concentrations, June 2002.

Similar indexed content

Compare copies and versions →