COPC World Trade Center Report, 50 pages

Machine-extracted title · confidence 50%

COPC committee report on World Trade Center contaminants with multi-agency authors.

NYC-WTC_000348649–000348698
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Contact Frequency fCF) Michaud et al (1994) assumed 8 contacts per day, apparently based on professional judgment. Low-end values of 1/day and "worst-case" rates of 24/day (3/hour) may be assumed as a matter of professional judgment; such exposure would obviously involve a very physical job with frequent contact with the walls and floor. The value recommended here is 16 contacts per day and is based on professional judgement. If available, site-specific activity data should take precedence.

Fraction Transferred Itnm Surface to Skin (FTSSI This will vary depending on type of surface, type of residual, hand condition, force of contact, etc. Rodes et al. 2001 conducted experiments on particle transfer to dry skin and measured transfers of 10% from carpets and 50% from hard surfaces. These transfer efficiencies were found to decline with repeated contacts. The OPP guidance recommends 5% of application rate for carpets and 10 % for hard surfaces (EPA, 1997a). USEPA has previously assumed transfer of 0.5 for PCBs (EPA, 1987) based on an Office of Toxic Substances (OTS) assessment. Michaud et al (1994) assumed 0.5 for PCBs and dioxins, but stated that 0.1 might be more realistic. In developing re-entry guidelines for the Binghamton State Office Building after a fire, a 100% transfer was assumed (Kim and Hawley, 1985). In a study of Malathion uptake from different surfaces, USEPA-EMSL found that FTSS of malathion from painted sheetrock to human hands was only 0.0003. (Mean transfer from vinyl flooring to hands was 0.0018, and from carpet to hands was 0.0152.) Malathion is a pesticide assumed to have lipophilicity more similar to PCBs than to volatiles or metals. However, the representativeness of such a number for PCBs and dioxins is unknown. PCBs are more lipophilic (have higher Kows) than malathion. A value of 5% is recommended here. Although this is on the low end of the literature values, when combined with the high contact frequency, it provides a fairly high total transfer to skin.

Exposure Frequency (EFI A value of 365 days/year is used to represent a full time resident.

Exposure Duration (EDI A value of 30 years is assumed to match upper bound estimate of time in a residence (EPA, 1997b).

Fraction Transferred from Skin to Mouth (FTSMI Michaud et al (1994) assumed that all of the residues deposited on the fingertips would be transferred to the mouth, twice per day. A similar approach is used in the OPP guidelines. In the Binghamton re-entry guideline derivation, a range of factors were used: 0,05, 0.1, and 0.25 representing the fi-action of residue on hand that is transferred to the mouth (Kim and Hawley, 1985). A similar value of 10% is recommended here.

Oral Absorption Fraction (ABSO) For chemicals whose dose-response parameters are based on experiments in which the absorption fraction is similar to the one expected in the exposure scenario, there is no need to adjust the RfD

4

CITY_21MC100_003012134

NYC-WTC_000348692

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348692Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →