NYSDOH/PD monitoring lab report, WTC 2001

Machine-extracted title · confidence 49%

NYSDOH and NYPD monitoring lab report for World Trade Center site with metal and dust exposure data.

NYC-WTC_000348346–000348347
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

CO-3 Search of nitrogen dioxide <=0.05 ppm. 1 ppm. (STEL) NYC Dept, of debris - east 260 nitric oxide 0.08 ppm. 25 ppm. Corrections - side of N. ESU Tower carbon monoxide < 1 ppm. 35 ppm 10 ppm. (Peak) 200 ppm CO-2 Search of 274 petroleum distillates 0.013 ppm. 400 ppm. NYC Dept, of debris - east benzene 0.011 ppm. 1 ppm. Corrections - side of N. ethyl alcohol 0.085 ppm. 1000 ppm. ESU Tower

CO-4 Search of 272 hydrochloric acid ND 7 mg/m’ (Ceiling Limit) NYC Dept, of debris - east hydrofluoric acid ND 3 ppm. Corrections - side of N. nitric acid ND 5 mg/m’ ESU Tower phosphoric acid 1 mg/'m’ sulfiiric acid 0.04 mg/ms (s) 1 mg/m’

568 carbon monoxide < 1 ppm. 35 ppm 12 ppm. (Peak) 200 ppm

TWA = Time Weighted Average PEL = Permissible Exposure Limit PESH = NYS Public Employee Safety and Health Bureau f/cc = Fibers per Cubic Centimeter ppm = parts per million mg/m’ = milligrams per cubic meter STEL = Short Term Exposure Limit Peak = Highest Level Seen During Test ND = not detected NA = not Applicable % = Percent < = Less Than <= = Less Than or Equal To

Analytical Method for total dust is based on NIOSH 0600 Analytical Method for silica is based on OSHA1D142 and NIOSH 7500 Analytical Method for metals is based on OSHA ID 125G

* =Metals scan also included; aluminum, chromium, copper, magnesium, mangenese, molybdenum, nickel, and zinc. ’ = The Action Level for lead is 0.030 mg/m’ ’ = Cassette sample was overloaded with particulate material for the purpose of PCM or TEM analysis * = The Ceiling Limit for carbon monoxide is to be measured over a 5 minute sample. = Results may include soluble non-sulfuric acid sulfate salts

CITY_21MC100_011087964

NYC-WTC_000348347

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348347Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →