NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: Warren & Panzer Volume (liters): 1560
Lab Group #: 8608 Filter Type / Filter Area: MCE 385 mm-
Lab Sample #: 3 Grid Opening Size: 0.01124
Client Sample #: 03 Area Examined: 0.0562 mm^
GRID BOX: Magnification: 20,000
GRID ID: Accelerating Voltage: 100 KeV
# Grid Openings: 5 Analysis Date: 7/28/02
Analysis Performed By:
ROMAN PEYSAKHOV
GO, Structure Structure Type Length ID of Stnjcture NorN EDS
(Nonadb
No F B C M >=05 p :>=5p Chrys Amphibole Nonasb Ambig/ND
No Elements)
<5tJ
/^^
s
zzzz
JL
/(
Struct = > 0.5p > 5:1 Aspect Ratio Grid acceptance:
Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
least 20 unfolded or overlapped grid squares <5% F B C M >5|j
EDS spectrum conforming to laboratory holes or opaque areas
identification criteria observed Chrysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
Tremolite
M = Matrix Non-Identified
Actinolite
NSC = No Structures Detected
CITY_DEP_60BROAD_MCGIVNEY_SUBP_000004369
NYC-WTC_000347039