Chain-of-custody: bulk sampling and TEM

Machine-extracted title · confidence 50%

Chain-of-custody addressing bulk sampling and TEM analysis for asbestos assessment.

NYC-WTC_000342677–000342680
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EPA or USEPA: United States Environmental Protection Agency.

Homogeneous Work Area: Portion of the Work Area that contains one type of ACM and/or where one type of abatement is used.

Phase Contrast Microscopy: “PCM” shall mean the measurement protocol for the assessment for the fiber content of air. For PCM analysis, the clearance air monitoring shall be considered satisfactory when every sample is less than or equal to 0.01 f/cc or the background concentrations, whichever is greater.

Polarized Light Microscopy: “PLM”shaIl mean the measurement protocol for the assessment for the asbestos content of bulk materials. For PLM analysis, the New York City and EPA Regulatory limit is 1.0%.

Transmission Electron Microscopy: “TEM”shall mean the measurement protocol for the assessment for the asbestos fiber content of air. For TEM analysis, the clearance air monitoring shall be considered satisfactory when the requirements stated in 40 CFR Part 763, Subpart E, Appendix A, Section IV are met. For the purposes of our testing the regulatory limit is 70 asbestos structures per mm2.

4.0 Scope of Work 4.1 Bulk Sampling Procedures

ALC’s licensed technicians worked under the guidance provided by the EPA guidelines for asbestos-'Asbestos in Buildines: Simplify Sampling Scheme for Friable Surfacine Materials." This sampling procedure uses random sampling to ensure that the samples are representative of the sampling area. ALC’s inspectors:

1. Identified all friable surfacing materials and grouped them into homogenous sampling areas by floor 2. Prepared diagrams of each sampling area 3. Determine the number of samples to collect (9 samples per homogenous areas are recommended) Determine samplmg locations 4. Collect samples 5. Fill out chain of custody 6. Send samples to a qualified laboratory

Due to the insufficient amount of dust and debris in the apartment units and public areas of the building, we were unable to collect the optimum number of samples suggested in the above referenced guidelines.

With the guidance of the above referenced document and NYCDEP we went to each floor and assessed each apartment on each floor for visible dust and debris. Upon completion of the initial assessment and bulk sample collection, ALC determined that there were no elevated asbestos levels present above the guidelines in any of the apartments where samples were taken.

If any dust and/or debris was found in the apartment we collected a bulk sample and sent it to the laboratory for analysis.

If no sample could be taken due to insufficient material present at the time we were in the apartment, the inspector documented this on the log.

-3,

CITY_DEP_WORBY_CANNATA_SUBP_000006519

NYC-WTC_000342678

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342678Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342638

TEM and bulk sampling protocol and results for multiple apartments.

Similar indexed content

NYC-WTC_000342619

Narrative on bulk sampling, visual assessments, air monitoring; TEM samples collected.

Similar indexed content

Compare copies and versions →