Bulk sampling and TEM monitoring, Building 400

Machine-extracted title · confidence 38%

AB asbestos assessment with bulk sampling and TEM air monitoring across floors, Oct 2001.

NYC-WTC_000342664–000342667
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

^^ings and Conclusions IB- yve (12) initial background air samples were collected and analyzed at building 400. Twelve (12) inles were analyzed via phase contrast microscopy (PCM) and two (2) were analyzed via Transmission ^on Microscopy (TEM). All were below the permissible limits.

K Based on EPA Guidelines, we collected one hundred fifty-eight (158) bulk samples and analyzed them via K Polarized Light Microscopy (PLM) Methodology. One (1) sample collected from one apartment was found B to be slightly above the regulatory limits of 1 %. Zero (0) were found to be above the regulatory limits I upon further analysis at a second laboratory for quality control purposes. However, certified asbestos f abatement contractors hired independently by the owner, were used to clean the specific apartment and the E areas were cleared by ALC via TEM air sampling. All air samples were found to be well below the permissible limits and the tenants where this cleaning took place have been notified of the clearance.

One hundred seventy (170) air samples were collected and analyzed via TEM Methodology. The results indicated that the living areas achieved the acceptance criteria below <70 structures per mm2 set by the above regulations.

6. Limitations and Exclusions All the professional opinions presented in this report are based solely on the scope of work conducted and sources referred to in our report. The data presented by ALC in this report was collected and analyzed using generally accepted industry methods and practices at the time the report was generated. This report represents the conditions, locations, and materials that were observed at the time the fieldwork was conducted. No inferences regarding other conditions, locations, or materials, at a later or earlier time may be made based on the contents of the report. No other warranty, express or limited is made. ALC’s liability and that of its contractors and subcontractors, arising from any services rendered hereunder, shall not exceed the total fee paid by the client to ALC for this project. This report was prepared for the sole use of our client. The use of this report by anyone other than our client or ALC is strictly prohibited without the expressed written consent of ALC. Portions of this report may not be used independent of the entire report.

& CITY_DEP_WORBY_CANNATA_SUBP_000006487

NYC-WTC_000342667

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342667Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342629

Summary of bulk and TEM sampling with lab analysis and quality control.

Similar indexed content

Compare copies and versions →