Air sample results, 2/22/02–3/1/02

Machine-extracted title · confidence 40%

Summary of lab results and direct readings showing personal vs area samples and 50% OEL references.

NYC-WTC_000342017–000342018
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Liberty Mutual.

Industrial Hygiene Air Sample Results Summary for Week of 2/22/02 to 3/1/02

Attached is a summary of the laboratory results reported and direct reading measurements completed during the week of February 22, 2002 to March 1, 2002. The air samples were collected and the measurements were made by ATC Associates at the World Trade Center site.

The majority of the samples collected by ATC are “personal samples”, meaning that the worker wore the sampling device. Most of results have shown exposure levels to be below 50% of the shift adjusted occupational exposure limits. The exceptions were:

• Quartz concentration as follows: • 67% of the shift adjusted OEL on a torch cutter at WTC 6. • 83% of the shift adjusted OEL on a flagger in basement levels of WTC 6. • 71% of the shift adjusted OEL on a torch cutter at WTC 6. • 83% of the shift adjusted OEL on a driller in basement levels of WTC 6. • Asbestos concentrations as follows: • 56% of the shift adjusted OEL on an operator at the WTC 1 site. • Diesel exhaust particulate concentration as follows: • 50% of the shift adjusted OEL on a torch cutter at the WTC 5 site. • 8 hour equivalent rime-weighted average noise levels above 90 dBA as follows: • 95 dBA for a laborer in WTC 6. • 96 dBA for a Kainatsu 750 operator at WTC 4. • 101 dBA for jack hammer operator in WTC 6. • 94 dBA for Bobcat operator in WTC 6 • 93 dBA for a Kamatsu 600 operator at WTC 4. • 95 dBA for a spotter in WTC 6. • 92 dBA for a Bobcat operator in WTC 6. * 96 dBA for a driller in WTC 6. • 95 dBA for Bobcat operator in WTC 6 • 97 dBA for operator of a Bobcat with a jackhammer attachment in WTC 6. • 93 dBA for a flagger (location not specified).

Elevated exposures to asbestos are based on the results of analysis by phase contrast microscopy (PCM). This method counts all fibers detected that meet the criteria of “fiber”. Materials that are not asbestos may be included in the reported analysis. These samples have been submitted for further analysis by transmission electron microscopy (TEM) to make a definitive determination of the fibers detected by PCM analysis.

Although no elevated hydrogen sulfide results were found during the week. Liberty Mutual has recommended continuous monitoring for hydrogen sulfide during work in excavations. In past weeks, we have had a few quantifiable hydrogen sulfide results (one area sample was actually above the OEL). Also, there have been many anecdotal reports of hydrogen sulfide smells. Because of the insidious nature and serious effects of exposures to excessive levels of hydrogen sulfide , we feel that

CITY_21MC100_002989034

NYC-WTC_000342017

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342017Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →