ES&H air monitoring data, prelim, Oct 20, 2001

Machine-extracted title · confidence 36%

Browser-rendered ES&H air data page; OSHA PEL-TWA data with.[name] exceedances and area listings.

NYC-WTC_000341965–000341967
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z o A O

I io ES&H Air Monitoring Data preliminary, October 20, 2001 co

o ■D c o o CT Ca5 Air Contaminant OSHA PEL-TWA, Work Area Total Number of Samples Percent (number) of Statistical Breakdown by o' MDL/QA limits Collected Samples Exceeding OSHA Work Area ■D CD O> Per Work Area PEL- TWA o O> 3. Lead 50 micrograms per cubic meter AMEC 18 0% (0) 12 of 18 samples met QA 03

(Hg/m’) limits. o o May include both OSHA PEL-TWA Highest TWA was 9.7 o contaminated airborne dust pg/m’. c and metal fume from burning 3 operations. Sampling MDL is 1.5 milligrams of lead 15 of 18 samples less then CD O represents breathing zone of per sample . MDL. worker and does not consider protection provided by QA limits require minimum of 7 BOVIS 27 0%(0) 23 of 27 SAMPLES met QA respirator. hours sample for TWA trip limits. blanks without lead exceeding Highest TWA was 16.5 MDL, and no visible damage to pg/m’. filter 14 of 27 samples less then MDL.

TULLY 14 0%(0) 12 of 14 samples met QA limits. Highest TWA was 6.3 pg/m’. 11 of 14 samples less then MDL. TURNER 18 6%(1 of 18) 12 of 18 samples met QA 1.3% OF ALL LEAD limits. SAMPLES Highest TWA was 113.1 pg/m’. 14 of 18 samples less then MDL

o H H

to

s o o 1^ o I hj

co 3 co (JI

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000341966Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000360526

Preliminary air monitoring data with OSHA PEL-TWA comparisons for WTC site.

Similar indexed content

Compare copies and versions →