NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan December 6, 2002
Air Sampling for Hydrocarbons, Metals, Mercury & Silica Page 2
P. S. 89(Manhattan) ATC Project No. 15-19125-0297
Analysis of the HC was performed by capillary gas chromatography/flame ionization
detection (NIOSH Methods 1003, 1005, 1022, 1300, 1500, 1501). Each sample was
analyzed for a panel of sixteen (16) specific HC compounds. In addition, two non
identified peaks, A-hydrocarbons and B-hydrocarbons, were reported. The A-
hydrocarbons are those, such as gasoline or light alcohols, with boiling points less than
that of benzene (176°F). The B-hydrocarbons are those, such as mineral spirits or
petroleum naphtha, with boiling points greater than that of benzene.
Analysis of the metal samples was performed inductively coupled argon plasma/atomic
emission spectroscopy according to NIOSII Method 7300M. Each sample was analyzed
for eleven (11) metals.
Analysis of the mercury samples was performed by means of a mercury analyzer
according to NIOSH Method 6009.
Analysis for silica was performed by x-ray diffraction according to OSHA Method 142.
Copies of the analytical laboratory reports are attached.
SAMPING LOCATIONS
Four different sampling locations were selected for HC, mercury and metals. They were
as follows:
Play ground North; Play ground South; Hallway outside the cafeteria; and Roof.
Respirable dust (silica) samples were collected from the following locations:
First floor hallway outside cafeteria (North); First floor hallway outside cafeteria
(South); Cafeteria; 2"‘’ Floor hallway south; 4* floor hallway south; Room 202;
Gymnasium; Auditorium; Room 204; and Room 228.
HYDROCARBON RESULTS
Each sample was analyzed for the following sixteen hydrocarbon (HC) compounds:
Pentane, Acetone, Methylene chloride, Hexane, Chloroform, Methyl chloroform, Total
Other A Hydrocarbons, Benzene, 1, 2-Dichloroethane, Trichloroethylene, Toluene,
Perchloroethylene (tetrachloroethylene). Chlorobenzene, Ethylbenzene, Styrene, Cumene
(isopropylbenzene), Xylenes, Total Other B Hydrocarbons. The limit of detection for
each compound was 0.020 milligrams per sample. The airborne concentrations were
calculated by dividing the amount found in the sample by the volume of air collected and
converting the quotient to parts per million (ppm).
No hydrocarbons were found above the limits of detection in any of the samples
collected.