NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

Chemical analyses, PCDD/PCDF, ATC

Machine-extracted title · confidence 42%

Laboratory report of PCDD/PCDF analyses for ATC project at DOE.

NYC-WTC_000340732–000340744
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 ^ace Analytical’ Minneapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT: PCDD/PCDF ANALYSES DATE: October 1,2002

PAGE: 2 REPORT NO: 02-1061637

DISCUSSION (Cont.)

A laboratory method blank was prepared and analyzed with the sample batch as part of our routine quality control procedures. The results, found at the beginning of Appendix B, show the blank to contain a trace level of non-2,3,7,8-substituted TCDD. The value was below the calibration range for this method. One sample contained this isomer at a level similar to that seen in the blank and is flagged "B" on the data summary sheet. In general, levels less than ten times the background are not considered statistically different from the background. This indicates that the sample processing procedures did not significantly impact the results of the analyses.

Laboratory spike samples were also prepared with the sample batch by extracting a clean wipe that had been fortified with native standard materials. The results, found at the end of Appendix B, show that the spiked native compounds were recovered at 93-106% with relative percent differences of 3.0-7.0%. This indicates high degrees of accuracy and precision for these determinations.

REMARKS

The sample extracts will be retained for a period of 30 days from the date of this report and then discarded unless other arrangements are made. The raw mass spectral data will be archived on magnetic tape for a period of not less than one year. Questions regarding the data contained in this report may be directed to the authors at the numbers provided below.

Pace Analytical Services, Inc.

9roi^t Manager, Dio^lps f63'2) 607-6383

REPORT OF LABORATORY ANALYSIS This report shall not he reproduced, except in full,. without the written consent of Pace Analytical Services, Inc.

/nebci CITY_21MC1OO_O12158283

NYC-WTC_000340733

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340733Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000353323

Lab report of PCDD/PCDF analysis for ATC project at PS 124M.

Similar indexed content

PCDD/PCDF analyses, ATC, Oct 2002

NYC-WTC_000317150

Chemical analyses report for PCP/PCDFs on four samples submitted by ATC Associates, Oct 2002.

Similar indexed content