NYC-WTC_000359970
IAQ field report for PS 89M with date June 2002 noted.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC report of indoor air quality for P.S. 89M, 201 Warren Street, Jun 2002.
NYC-WTC_000340449–000340452OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
06/19/2002 10:07 FAI 212 353 8306 ATC @005/014
Mr. Bernard P. Orlan Indoor Air Quality' Assessment ^age 4 P. S. 89M__________ ________ ______________________ ATC Project No-15-19125-0297 outdoor respirable particulate concentration measurements ranged between 46 pg/m^ to 51 g/m^ with an average of 49 ug/m^.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TYOC Concentrations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm
OBSERVATIONS
During this assessment, ATC noted the following: • The school building was occupied at the time of the assessment, • No smoke odor was detected in the building • The interior of the building appeared clean and free of dust and debris-
FINDINGS Based on the real-time measurements, the following findings arc presented: 1. Concentrations of CO and TVOCs were below applicable standards and guidelines. 2. Sixty-three (63) of die indoor measurements for temperature were below the range of 73 to 79®F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during tlie summer season. 3. All of the indoor measurements for CO2 were within tlie ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. 4. All of the indoor measurements for relative humidity were within the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. 5, None of the indoor measurements for PM2,5 were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter or above the USEPA recommended concentration of 40 gg/m^ for sensitive individuals and children.
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about tins report, please call (212) 353-82S0, ext 211 or 212.
Sincerely, Reviewed by: ATCASSOCIA T£S INC.
'Yiaimis Efstathiou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager Industrial Hygiene Division Attachment
CITY_21MC100_009261449
NYC-WTC_000340452
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000359970
IAQ field report for PS 89M with date June 2002 noted.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340699
ATC IAQ measurements conducted May 2, 2002 for P.S. 89M, NYC DOE.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328377
ATC reports indoor air quality data collected May 20–21, 2002 at PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328340
ATC provides IAQ measurements for PS 89M; BOE requested air quality evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313917
ATC indoor air quality measurements collected June 20, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369114
ATC Associates indoor air quality report for P.S. 89M, May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313905
ATC IAQ measurements for PS 89M conducted June 19, 2002 per BOE.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000210980
Report of indoor air quality measurements conducted at P.S. 89M on May 16, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340679
ATC May 7, 2002 letter to BOE regarding IAQ measurements at PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369845
IAQ measurements at P.S. 89M provided to BOE, dated May 22, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340627
ATC May 16, 2002 memo re IAQ measurements at PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000359970
IAQ field report for PS 89M with date June 2002 noted.
Similar indexed content
NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
Similar indexed content
NYC-WTC_000340699
ATC IAQ measurements conducted May 2, 2002 for P.S. 89M, NYC DOE.
Similar indexed content
NYC-WTC_000328377
ATC reports indoor air quality data collected May 20–21, 2002 at PS 89M.
Similar indexed content
NYC-WTC_000328340
ATC provides IAQ measurements for PS 89M; BOE requested air quality evaluation.
Similar indexed content