Client: Dept of Design & Construction Report #: 04DDC-69532 Page 2of 2
30-30 Thompson Ave. Date: 06/07/04
Long Island City, N.Y. 11101 Break Date; 07/05/04 Item #:
Project: DDC-C-889 Contract: HWMWTCAIE
CONCRETE FIELD DATA (ASTM C192)
Truck Ticket Batch Disch. Samp. % Air Slump Cone. Unit Wt. Field Design
No. No. Time Time Time Cont. (Inch) Temp, F (PCF) Set# Strength (PSI)
B-3200
Location(s) of Pour:
Supplier: Contractor: Inspector: Client
Weather: Air Temp. Total Yardage Placed:
COMPRESSIVE STRENGTH OF CONCRETE TEST CYLINDERS (ASTM C39) (6” D x 12” HI
Field Seal Date Date Age, Cross Total Fracture Strength Aging Correct Comp.
# # Cast Tested Days Sect. Area, Load Type (PSI) factor strength
(sq. in.) (Lbs.) (PSI)
13 13 06/07/04 06/10/04 3 28.27 101000 E 3573 3573
14 14 06/07/04 06/10/04 3 28.27 97500 D 3449 3449
15 15 06/07/04 07/05/04 28 28.27 136500 E 4828 4828
16 16 06/07/04 07/05/04 28 28.27 140500 E 4970 4970
17 17 06/07/04 06/10/04 3 28.27 96000 D 3398 3398
18 18 06/07/04 06/10/04 3 28.27 98500 D 3484 3484
19 19 06/07/04 07/05/04 28 28.27 140000 E 4952 4952
20 20 06/07/04 07/05/04 - 28 28.27 132500 D 4687 4687
A B C D E
Cone Cone &
0Cone & Shear Columnar
Submitted By: Materials Testi
Split Shear
The above reported data is the property of the client. No reproduction of the
above data without the sole permission of Materials Testing Lab, Inc.
Materials Testing accepts no liability for work executed by others.
The MT Group: • New York City • Long Island • Edison, NJ • Wallingford, CT • Dover, DE • Bethlehem, PA
CITY_21MC100_007224278
NYC-WTC_000340166
OCR can misread numbers and units. Confirm readings against the page image before using them.