Respirable Silica; The overwhelming majority of 1073 silica samples (excluding bulk and blank
samples) show no detectable levels of airborne silica. However, 72 exposures
exceeded the PEL. The highest sample result was approximately twenty-one
times the OSHA limit (jack hammering concrete 16 feet below grade). The
other elevated exposures were approximately one to fourteen times the OSHA
limit. These exposures occurred during: 1) pre-drilling /slurry wall 2) jack
harninering, 3) rubble removal and loading operations near the Winter Garden;
4) during the breaking up of concrete in the pit; 5) while drilling the concrete
slurry wall, 6) flagging operations in pit, and 7) while chipping concrete with
power tools during demolition activities at 7 WTC’s parking garage. Most of
the work areas where apparent overexposures to silica occurred were in the
rubble pile/pit; an area where OSHA continues to encourage the use of
respiratory protection.
Organic
Compounds; OSHA has taken a total of 699 samples (excluding bulk and blank samples)
for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene.
2-butanone, carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde, Freon
R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDT),
perchloroethylene, polynuclear aromatics, phosgene, styrene, toluene, 1-3
butadiene, trichloroethylene, vinyl chloride, glutaraldehyde, and xylene.
Screening samples initially showed elevated levels of some organic chemicals
I; - resulting from the fires burning in the rubble pile. Subsequent personal and
area samples show worker exposure levels to be below OSHA limits.
However, one personal sample result for a benzene sample taken was found to
be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found
on a backlioe operator moving debris on 10/7/01. See information below for
the specific counts in regards to polynuclear aromatics, Freon R-22, phosgene
and dioxin.
Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot
spots in (and around the perimeter of) the rubble pile. Dioxin levels detected
Page 2 of 4
CITY_21MC100_007222254
NYC-WTC_000339782