Technology overview, NYC health lab report

Machine-extracted title · confidence 25%

Laboratory note on technology tools; unclear project context.

NYC-WTC_000338737–000338912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Article I Geiser et al.

generated by jet nebulization of droplets of measured by pneumotachography and laser­ preserve the aqueous lining layer and especially suspensions of MMVF 10a fibers (2 mg/mL light scattering photometry. Because the fibers also the surfactant film at the air liquid inter in 100% ethanol) into a particle-free air used in this study were heterogeneous in size, face (Geiser et al. 1997; Lee ct al, 1995; Sims stream. The fibers were then dried, charge number estimates are of directional value only. et al. 1991; Thurston et al. 1976). However, it equilibrated, and concentrated before being Aerosols were inhaled for 5-12 min, until a is not known whether material that is not sub­ injected into a reservoir and transferred to the sufficient number of fibers for microscopic mersed in the surface-lining layer may be dis­ inhalation/exhalarion channel. The deeply analysi.s were deposited. Immediately there­ located by thi.s procedure. anesthetized and completely relaxed hamsters after, the lungs were prepared for intravascular Because it was the aim. of this study to inhaled the aerosol directly from the reservoir perfusion fixation. investigate the location of deposited fibers through an intratracheal cannula during con­ We collected aerosol samples on filters and with respect to the inner surface of the lungs, tinuous negative-pressure ventilation. They analyzed the fiber size distribution (Figure 2). the fixative solutions were applied by vascular were ventilated with a tidal volume {Vy-) of The average length of 200 fibers measured by perfusion via the pulmonary artery, which 0.95 ± 0.06 mL (mean ± SD)—maintained at light microscopy was 16 ± 13 pm (mean + allows the airways and alveoli to remain in 70-80% of total lung capacity—and a breath­ SD; range, 1-66 pm); the average diameter their natural air-filled state. Sequential ing frequency (/) of 61 ± 1 breath/min (mean was 1.1 + 0.2 pm (range, 0.6-1.7 pm). The intravascular perfusion of buffered 2.5% glu­ ± SD), which equals slow, deep breathing average length-to-diameter ratio was 15.6 + taraldehyde, 1% osmium tetroxide, and 0.5% (Inglis 1980). The breathing parameters and 13.3 (range, 1.1-64.0). Twenty fibers had a uranyl acetate (Bachofen et al. 1982; Im Hof the number of inhaled and exhaled fibers were length-to-diameter ratio of < 3; hence, the par­ et al. 1989; Weibel 1984) has been shown to ticulate fraction of MMVF 10a in the aerosol well preserve the surface-lining layer with its was 10%. phagocytic cells and the surfactant film at the Lung fixation. Whole lungs can be pre­ air-liquid interface of intrapulmonary con­ served for morphologic analysis by the intro­ ducting airw'ays and alveoli in laboratory ani­ duction of a suitable fixative into the airways of mals (Geiser et al. 1997: Gil and Weibel a collapsed lung or by deliver}? of the fixatives 1969, 1971). to the lungs via the blood vessels (Weibel All lungs were fixed within 23 + 2 min of 1984). The instillation of aqueous fixative the initial inhalation. The short time between solutions into the airways is not suitable for the inhalation and lung fixation allows the inves­ investigation of the inner surface of the lungs tigation ot fibers as close as possible to where because the surface-lining layer and all its cellu­ they were deposited. After fixation, the lungs lar and acellular constituents are dislocated were removed from the thorax and split into from their native positions and transferred to left lung, right lung, and accessory lobe other regions of the organ (Brain et al. 1984). (Geiser et al. 1990). Figure 1. Scanning electron micrograph of the Instillation of airways with nonpolar fixative fibers as they were used for aerosol generation. solutions (1% osmium cetroxide dissolved in They have a cylindrical shape and are of variable lengths and diameters. Bar = 10 pm. perfluorocarbon) has been demonstrated to

ICO 100 gn 80 AJ 90 80 70 co £ 60 s» £ !2V 50 43 IZ 40 30 30 20 20 10 0 nl lnnnr-,r-,- <5 5-10 11-15 16-20 21-30 3M0 41-50 >60 10 0 <0.5 0,5-1,0 1.1-1.5 >1.5 Length {pm) Diameter (uin) Figure 2. Size distributions of MMVF 10a in the aerosol; the fibers {n = 200) were measured on iight micrographs.

100 90 □ ZZj Airways ZJ Aivcoli 100 90 a 80 80 70 70 60 55 60 (A g 50 QJ 50 S to 40 £ 30 30 Figure 4. Scanning electron micrograph of a fiber 20 20 retained in an intrapulmonary conducting airway. 10 0 ml 10 0 1 (4) Overview of the retention site (boxed area); bar = 500 pm. Abbreviations: A, alveoli; AW, intrapul­ Totally covered Partially covered Not covered Totally covered Partially coversd Not covered monary conducting airway: PA, pulmonary artery. Figure 3. SEM (4) and TEM (S) analysis of fibers retained on the surfaces in the intrapulmonary conducting (B) The fiber is completely covered by the surface­ airways and in the alveoli (defined by amount of lung lining-layer material covering fibers). lining layer (arrowi; bar= 5 pm.

896 VOLUME 1 n I NUMBER 7 I June 2003 • Environmental Health Perspectives

CITY_21MC100_012178526

NYC-WTC_000338804

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338804Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →