IV. Sampling Parameters: o
o
Parameter Sample Type Indoor/Outdoor Rationale for Selection c
Asbestos breathing ht., I/O known use in building construction, evidence of 3
I o
time-weighted pre.sence in early air sampling and in settled dust, I 3
air known inhalation carcinogen
on holdTfotal Suspended breathing ht., o Characterize amount of airborne dust that is
particulates Continuous, real inlialable (<IOO pm aerodynamic diameter)
time, air
PMI0andPM2.5 breathing ht.. O Characterize the amount of airborne dust that is
Continuous, real respirable
time, air
Inhalable (<100pni)* breathing hl., I/O To determine relative amoimls of each fraction present
I
thoracic (<10pm)' time-weigh ted, and to have each fraction analyzed for silica, gypsum, I
respirable (<2.5pm)' air mica, fiberglass, and calcite to qualitatively determine
I
potential hazards.
Respirable breathing ht., I/O Known component of concrete, evidence of
crystalline silica time-weighted, presence in some settled dust samples, known
air inhalation carcinogen.
pH" dust I/O Concrete has a high pH, ifdust has a high pH, it may be
contributing to reported symptoms of ENT irritation
I
Asbestos" dust I/O Determine if asbestos is present in dust
gypsum,silica, mica, dust I/O Associated with building materials (concrete,
fiberglass, calcite” drywall) and known to be irritating to ENT
magnesium dust I/O May act as a tracer for WTC-related dust, levels found in
Q metals analysis of settled dust from 16,000-29,000 ppm
’ results will be used to better understand the potential for ENT and respiratory irritation, and possibly for determining the possibility of acutc/chronic health