Follow up Recommendations Based on Sampling Results from ATSDR’s Residential Sampling
1 I
I
CD
Asbestos level (bulk and air) Sequential steps for follow up CommentsNotes:
Settled dust 1. Clean-up Clean-up should follow OSHA standards for training and
> 1% asbestos w/w (PLM) 2 Resample air and bulk worker protection and any state laws for licensing.
3 Evaluate data Consideration should be given to removing hard to clean
air 4 Determine next actions based on furnishings, like carpet and upholstery, if sampling data
any level follow up recommendations remains elevated after repeated cleaning s
Settled dust 1. Clean-up Consideration should be given to removing hard to clean
>Detection Limit - < 1 % 2. Resample air and bulk furnishings, like carpet and upholstery, if sampling data
w/w (PLM) 3. Evaluate data remains elevated after repeated cleaning
4. Determine next actions based on
air follow up recommendations
> 0.01 f/cc (TEM)
Settled dust 1. Evaluate all appropriate data
>Detection Limit - < 1% related to asbestos (air. bulk, Special attention should be paid to hard to clean surfaces.
w/w (PLM) personal monitors - PLM. XRD, (e.g., certain fabrics, furniture, carpet, and curtains).
PCM, TEM) S
air 2. Determine appropriate follow up
<0.01 fZee (TEM) based on professional judgement
3. If clean up is recommended,
resample and reevaluate results
Settled dust 1. Clean-up Remain advised of outdoor levels. If high levels are frequent
Non-detect (PLM) 2. Resample air retesting may be appropriate.
3. Evaluate air data
air 4. Determine follow up actions
> 0.01 f/cc (TEM)
Settled dust No further action