Results of Fiber Analyses

Results of fiber analyses in air and dust samples from 30 residential buildings (1-30) in lower Manhattan and 4 comparison buildings (31-34) above 59th Street. The range of values measured in the comparison buildings is shown in the summary of comparison areas above 59th Street.

Results From Air Samples Results From Dust Samples

Building Fibers in Air Asbestos in SVF in Air Asbestos in Asbestos in Dust SVF in Dust Number Sample Location PCM (f/cc) Air TEM (f/cc) SEM (f/cc) Dust PLM (%) TEM (%) PLM (%)

Summary of Comparison Areas Above 59th Street

Outside <.001-0.001 NA ND-<.000043 Not Sampled Not Sampled Not Sampled

Common <.001-0.002 NA ND-0.000043 ND ND ND

Residences <.001-0.003 NA ND-0.000087 ND ND ND

Results for Individual Buildings Sampled In Lower Manhattan (Buildings 1-30) 1 Outside 0.001 ND <1 22 1 Common <.001 Not Sampled Not Sampled Not Sampled 1 Residence 1 0.006 <.001 0.000162 ND NA 20 1 Residence 2 <.001 ND NA 20

2 Outside 0.003 <1 1.2 28 2 Outside co-located Not Sampled Not Sampled Not Sampled 1.3 NA 25 2 Common 0.005 <.001 0. fiiilil255 ND NA 27 2 Residence! <.001 ND NA 25 2 Residence 2 0.002 ND NA 20 2 Window sill Not Sampled Not Sampled NotSampled <1 <1 30

3 Outside <.001 Not Sampled Not Sampled Not Sampled 3 Res 2 co-located <.001 Not Sampled Not Sampled Not Sampled 3 Common <.001 Not Sampled Not Sampled Not Sampled 3 Residence 1 <.001 Not Sampled Not Sampled Not Sampled 3 Residence 2 <.001 Not Sampled Not Sampled Not Sampled

4 Outside 0.001 Not Sampled Not Sampled Not Sampled 4 Outside co-located <.001 Not Sampled Not Sampled Not Sampled 4 Common 0.001 ND <1 15 4 Common co-located 0.001 Not Sampled Not Sampled Not Sampled 4 Residence 1 <.001 ND <1 2

102

CITY_21MC100_011101200

NYC-WTC_000338162

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338162Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →