NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

AHERA/PCM guidance draft, Feb 2002

Machine-extracted title · confidence 37%

AHERA standard discussion; comparison with PCM-based risk-based approaches for asbestos at WTC.

NYC-WTC_000337675–000337677
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

width <.25 um are, generally, not visualized by PCM.

Measurement Reporting Units: Conversion from f/mm2 to f/cc

To accommodate a quantitative risk assessment paradigm, the AHERA standard must also be converted from f/mm2 to f/cc. As per the AHERA sampling criteria (i.e,, sample volume of 1,200 L, filter diameter of 25 mm), the standard of 70 f/mm2 converts to .022 f/cc as demonstrated below:

70 f X 385 mm2 (effective filter area of 25 mm filter) 1,200 Lx 1,000 cc/L

WTC Screening Levels

The draft risk-based screening analysis for WTC assumes an upper bound (continuous) exposure estimate of one year duration. Based on the IRIS inhalation unit risk of 2.3 E-I per (f/cc), excess lifetime cancer risk of 1 E-04 (one-in ten thousand) for a 70 year exposure duration equates to an asbestos concentration of .0004 f/cc. Adjusting the exposure duration to 1 year at a 1 E-04 cancer risk (target risk used for WTC screening values) yields an airborne asbestos concentration of .028 f/cc.

Conclusion

The above analysis indicates that continuous exposure to 70 f/mm2 (under the worst case assumption that all fibers >5 um) for a one year exposure duration would result in less than a one-in ten thousand excess lifetime cancer risk.

It is worth noting that the unit (f/mm2 to f/cc) conversion of the AHERA standard is a function of sample volume. The relationship is inverse. That is, the lower the sample volume the higher the asbestos concentration (f/cc). Thus, if a sample volume is sufficiently less than 1,200 L, the AHERA standard of 70 f/mm2 would convert to an airborne asbestos concentration that exceeds the one year, risk-based value of .028 f/cc. However, of greater importance to note is that to date less than 2 % of the samples have exceeded the AHERA standard of 70 f/mm2 and that the vast majority (approximately 80 - 90%) of fibers (from all sampling results) have been < 5 um in length.

In conclusion, when taken in its totality (i.e., individual sample results, length distribution of counted fibers, sample volume). The WTC airborne asbestos sampling data demonstrates that exposure to ambient air for a one year exposure duration is below WTC risk-based screening levels.

CITY_21MC100_003062937

NYC-WTC_000337676

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337676Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Asbestos FAQs (draft) · Box unavailable

NYC-WTC_000302883

Draft commonly asked questions about asbestos health effects, safe levels, and standards.

2 shared non-person entities · 1 shared topics · similarity 0.915

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →