NYC 9/11 Public Portal Document
Polychlorinated Biphenyls (PCBs) (December 6, 8, and H, 2001)
Eight air samples were analyzed from inside and outside PS 234 on December 6, 8 and
11, 2001. PCBs were not deterted in any of the 8 samples collected on any of the three
days.
Polycyclic Aromatic Hydrocarbons fPAHs) (December 6,8, and 11, 2001)
The only PAH compound detected in the samples from outside the school was
naphthalene, at concentrations from below the detection limit to 0.32 ug/m’, while inside
the school, naphthalene (ND to 0.69 ug/m’), 1-methylnaphthalene (ND to 0.49 ug/n?),
and 2-methylnaphthalene (ND to 0.92 ug/n?) were detected. Naphthalene is the major
constituent of mothballs, and all three compounds are found in cigarette smoke. The
detected concentrations are all within documented urban background levels. While there
are no relevant standards for these compounds, the USEPA Region 9 preliminary
remediation goal (PRG) for naphthalene in air, adjusted for a school exposure scenario, is
8.7 ug/m^ for naphthalene. There is no PRG for either I-methylnaphthalene or 2-
methylnaphthalene. Naphthalene concentrations in all samples were well below the
adjusted Region 9 PRG.
l)ioxinandDibenzofuTans(December6^95andl2j2()01)
Trace levels of dioxins were detected in all the indoor and outdoor samples collected on
all three days. Reported TCDD Equivalents (a measure of the toxicity of the dioxin and
dibenzofuran constituents detected in the sample expressed in terms of the toxicity of
2,3,7,8-tetrachloro-dibenzO “p-dioxin, the most potent of the dioxin isomers) were as
follows (in picograms per cubic meter, pg/m’):
Sate Indoor Concentration Outdoor Concentration
December 6 0.0078-0.028 pg/m’ 0,038-0,073 pgZm’
December 9 0.0079-0.022 pg/m’ 0.028-0.037 pg/m’
December 12 0.0013-0.0035 pg/n? 0.0014-0.0022 pg/m’
There are no relevant standards for dioxins in air in a school setting. USEPA is utilizing
a screening level of 160 pg/m’, assuming a one-year exposure, and 5.4 pg/m\ assuming a
30-year exposure. The USEPA Region 9 preliminary remediation goal (PRO) for dioxin
in air adjusted for a school exposure scenario is 0.126 pg/m’. The dioxin levels were all
well below any of these screening levels.
Mercury (December 7,9, and 12. 2001)
Mercury was not detected in any of 8 samples collected on December 7, 9, and 12, 2001
above the level detected in the method blank.
5
CITY_21MC100_006753561
NYC-WTC_000337665
OCR can misread numbers and units. Confirm readings against the page image before using them.