EPA/NYSDOH PCB assessment, Sept 2001

Machine-extracted title · confidence 43%

EPA/NYSDOH PCB distribution figures from 9/20/01 sampling at WTC area.

NYC-WTC_000337298–000337300
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

0.4 0.35 -♦-15 ng/L-Deo-98 I 0.3 -*-24 ng/L-Mar-98 ra •g 0.25 -Ar-9.9 ng/L-Aug-99 I 0-2 -•-7.0 ng/L - Dec-99 0.15 JL -O- 5.3 ng/L • Dec-99

1 - 0.05 0 1 2 34 5 6 7 8 9 10 homologues

Figure 2. CARP samples using TOPS, Hudson River, Harlem R, to Battery. 04---------- S 0.35---------- I 0.3------- —♦- 9.8 ng/L - Sep-98 c 0.25---------- -*- 6,0 ng/L - Mar-99 I 02- A 6.7 ng/L - Jut-99 g 0.15-------- § 0.1 £ 0,05 " 0 1 23456789 10 homologues

Figure 3. CARP samples using TOPS, Lower East River.

The average PCB concentration of the Hudson and East River grab samples taken on 9/20 by EPA was 12 ng/L. TOPS samples from the Hudson between the Harlem R. at the Battery and samples from the lower East River averaged 9.7 ng/L. The ambient water quality standard for PCB for protection of humans eating fish is 0.001 ngZL. The slightly lower value of the TOPS samples is probably due to the TOPS system rather than to actual differences in concentration.

Figure 1 shows that the Rector St sample was both more contaminated than the ambient samples (96 ng/L), and from heavier homologues. NYCDEP believes that the WTC transformers held about 100,000 gallons of "non-PCB” transformer fluid. The transformer fluid could have contained up to 50 ppm PCB and the PCB would have been either Aroclor 1254 or Aroclor 1260. The Rector St. pattern looks like it originated from Aroclor 1260.

The quality of the WTC grab sampling is somewhat weakened by its small sample size but nevertheless it is sufficient. The Procedural Blank was 0.42 ng/L and the field blank was 1.18 ng/L.

Some PCBs have dioxin-like properties. These are expressed as Toxic Equivalents (TEQs) to 2,3,7,8-TCDD. The average PCB TEQ from the CARP ambient samples taken

CITY_21MC100_003062270

NYC-WTC_000337299

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337299Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321069

Preliminary NYC/WTC sampling results for PCBs, PAHs, metals and TSS by EPA Region 2.

Similar indexed content

Compare copies and versions →