Mr. Bernard P. Orlan December 24, 2001 Air Sampling for Fungal Spores Page 2 P. S. 234(Manhattan) ATC Project No. 15-19125-0279

EVALUATION CRITERIA

For purposes of evaluating microbiological contaminants, ATC uses the values recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) in the publication Bioaerosols: Assessment and Control (1999) and the AIHA in the publication Field Guide for the Determination of Biological Contaminants in Environmental Samples (1996). Table 1 below lists the target guidelines for the bioaerosol parameters that ATC evaluated during this investigation. TABLE 1 TARGET GUIDELINES FOR BIOAEROSOLS EVALUATED

Fungi/Molds/Mildew Indoor samples are not dominated by AIHA (species comparison) species that are not found outdoors Fungi/Molds/Mildew Not significantly greater than outdoor air (density comparison) concentrations ACGIH and AIHA

Meeting one, some, or all of the listed values in the table does not assure that acceptable indoor air quality will be achieved at all times.

The assessment of bioaerosol data in regard to whether microbial contamination might be present is based on three primary criteria:

• The indoor levels of all species in relation to those outdoors; Indoor levels must be less than outdoor levels in order for the air quality to be considered acceptable; • The rank order of dominant species indoors in relation to those outdoors; and • The presence or absence of target species in the samples.

ATC has evaluated the sample results (presented in the Attachment) in light of these criteria. The following provides the results of our evaluation. Results are summarized in Table 2.

FUNGAL SPORE COUNTS

Basement area spore counts were low. The higher of the two basement samples was 322 fungal structures per cubic meter of air (fs/m^). The outdoor level was 2,067 fs/m^. Indoor vs. outdoor comparisons do not indicate the presence of amplified fungal growth indoors. The dominant spore type in all samples was Aspergillius/Penicillium-like spores. The results are reported this way as the spores of these two genera of fungi caimot be distinguished definitively by microscopic examination. The other spores identified indoors were Nigrospora and ascospores. Nigrospora is a common fungus that actively releases spores into the air. Ascospores are the asexual spores released by several fungi, such as Chaetomium or Eurotium. (A description of asexual vs. sexual spores of fungi is beyond the scope of this report). The identification of a single Nigrospora structure indoors (it was not found in the outdoor sample) is not significant. Such random occurrences in spore samples are not unusual.

CITY_21MC100_011101080

NYC-WTC_000336909

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000336909Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →