NYC-WTC_000336411
ATC IAQ report for Stuyvesant HS; measurements collected March 11, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC IAQ measurements collected on Mar 1, 2002 for Stuyvesant High School.
NYC-WTC_000336329–000336333OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 4, 2002 Indoor Air Quality Measurements Page 3 Stuyvesant High School (M477) ATC Project No. 15-19125-0246
Real-Time Environmental Measurements
ATC collected one hundred and twenty (120) sets of real-time environmental measurements consisting of one hundred and eighteen (118) in the school building and two (2) outdoors. All ten floors of the school were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded after 12:35 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 68.6°F to 73.9°F. All of the measurements were within the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature range was 36.2 to 45.2 °F.
Relative Humidity
The relative humidity indoors ranged from 18.6 percent to 36.6 percent. One hundred and thirteen (113) measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort.. The outdoor relative humidity levels were 22.1 and 24.1 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 510 ppm to 1550 ppm. One (1) of the CO2 measurements was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations were 563 and 577 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1277 ppm (background level + 700 ppm). Levels above the recommended maximum do not indicate a health nsk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 0 to 1 ppm.
Respirable Particulates (PM2j)
Respirable particulate concentrations* indoors ranged betw'een 2 pg/m^ to 17 pg/m^ with an average of approximately 10 pg/m^. None of the measurements were above the NPAAQS of 65 pg/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter or the USEPA recommendation of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentrations were 25 and 28 pg/m^.
CITY_21MC100_003061296
NYC-WTC_000336331
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000336411
ATC IAQ report for Stuyvesant HS; measurements collected March 11, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336335
ATC IAQ report for Stuyvesant High School dated Mar 4, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336311
ATC IAQ report for Stuyvesant High School dated Feb 28, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256164
Indoor air quality measurements conducted at Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256198
IAQ measurements collected for Stuyvesant High School in Feb–Mar 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256181
Report of IAQ measurements at Stuyvesant High School per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256216
IAQ measurements collected for Stuyvesant High School in Feb 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256233
IAQ measurements collected for Stuyvesant High School (Mar 2002).
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336353
ATC provides IAQ measurements at Stuyvesant High School for BOE evaluation, March 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336377
IAQ measurements collected at Stuyvesant High School; March 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000406788
Indoor air quality measurements at Stuyvesant High School conducted May 17, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256046
ATC memo for Stuyvesant High School IAQ measurements dated February 13, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270030
ATC IAQ measurements conducted March 18, 2002 at Stuyvesant High School for NYC BOE.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000402099
ATC IAQ measurements conducted on Feb 28, 2002 for Stuyvesant High School.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270018
ATC IAQ measurements conducted March 13, 2002 at Stuyvesant High School for NYC BOE.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336458
Indoor air quality measurements collected March 18, 2002 at Stuyvesant HS.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000336411
ATC IAQ report for Stuyvesant HS; measurements collected March 11, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270014
ATC report of IAQ measurements collected March 12, 2002 at Stuyvesant High School for NYC BOE.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
ATC IAQ report for Stuyvesant HS; measurements collected March 11, 2002.
Similar indexed content
NYC-WTC_000336335
ATC IAQ report for Stuyvesant High School dated Mar 4, 2002.
Similar indexed content
NYC-WTC_000336311
ATC IAQ report for Stuyvesant High School dated Feb 28, 2002.
Similar indexed content
Indoor air quality measurements conducted at Stuyvesant High School.
Similar indexed content
NYC-WTC_000256198
IAQ measurements collected for Stuyvesant High School in Feb–Mar 2002.
Similar indexed content