NYC-WTC_000377024
Indoor air quality measurements for High School for Leadership & [name].
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC IAQ measurements collected February 14, 2002 at the referenced school.
NYC-WTC_000335434–000335437OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan February 15,2002 Indoor Air Qua ity Assessment Page 3 H.S. for Leadership &. Pub. Sendee (M894) ATC Project No. 15-19125-0290
Real-Time environmental Measurements
ATC collected one hundred and forty (140) sets of real-time environmental measurements consisting of one hundred and thirty-four (134) in the school building and six (6) outdoors. AH fourteen floors of the school were surveyed. Field data sheets are found in the Attachment. Readings began at 8:35 A.M. and concluded after 3:15 P.M. The results are descnbed below.
Temperature
Indoor dry bulb temperature measurements ranged from 58.2°F to 74.3°F. Fourteen (14) of the measurements were below the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature range was 37.1 °F to 45.7°F.
Relative Humidity
The relative humidity indoors ranged from 18.3 percent to 35.9 percent. One hundred and twenty-eight (128) measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity range was 37.1 to 45.7 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 526 ppm to 1289 ppm. Thirteen (13) of the measurements were above the ASHRAE Standard 62-1999 recommended maximum concenfration of <700 ppm above the background level. The outdoor (background) CO] concentrations ranged from 412 ppm to 471 ppm. Therefore, the maximum acceptable level of COg at this location was 1171 ppm (background level + 700 ppm). The highest reading was recorded in Room 905, occupied by 23 people at around 1:55 P.M. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of COg indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 1-2 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 0-4 ppm.
Respirable Particulates ('PM2_s)
Respirable particulate concentrations* indoors ranged between 6 pg/m^ to 38 ug/m^ with an average 13 pg/m ’- None of the measurements were above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The outdoor respirable particulate concentrations ranged from 28 pg/m^ to 61 ug/ml with an average of 46 pg/m^.
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
CITY_21MC100_006752176
NYC-WTC_000335436
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000377024
Indoor air quality measurements for High School for Leadership & [name].
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335382
ATC IAQ measurements collected February 11, 2002 for the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335345
ATC IAQ measurements conducted February 6, 2002 at the school.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000376933
IAQ report correspondence from ATC to NYC BOE for M894.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000215155
Report summarizing indoor air quality measurements collected at a high school location in February 2002 to assess environmental conditions.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000376915
IAQ measurements report for M894 site at Trinity Place, BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335327
ATC reports IAQ measurements collected February 5–6, 2002 for NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000377084
Correspondence reporting indoor air quality measurements at a NYC school.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335364
ATC IAQ measurements collected February 8, 2002 for the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000215187
Report summarizing indoor air quality measurements collected at a high school location in late February 2002 to assess environmental conditions.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370407
ATC IAQ measurements conducted March 4, 2002 at the referenced NYC BOE school.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335452
ATC IAQ measurements collected February 15, 2002 at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000260537
ATC IAQ measurements collected June 7, 2002 at the referenced school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000377024
Indoor air quality measurements for High School for Leadership & [name].
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000260525
ATC IAQ measurements collected June 4, 2002 at the referenced school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000253655
IAQ measurement summary for PS 150M prior to re-occupancy, May 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335364
ATC IAQ measurements collected February 8, 2002 for the referenced school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000335382
ATC IAQ measurements collected February 11, 2002 for the referenced school.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000377024
Indoor air quality measurements for High School for Leadership & [name].
Similar indexed content
ATC IAQ measurements collected February 11, 2002 for the referenced school.
Similar indexed content
ATC IAQ measurements conducted February 6, 2002 at the school.
Similar indexed content
NYC-WTC_000376933
IAQ report correspondence from ATC to NYC BOE for M894.
Similar indexed content
NYC-WTC_000215155
Report summarizing indoor air quality measurements collected at a high school location in February 2002 to assess environmental conditions.
Similar indexed content