NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street-Suite 200
Minneapolis, MN 55414
TM
^ace Analytical__________
Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 812- 607-6444
Client - ATC
Client's Sample ID ATC-1223-234M-DX2
Lab Sample ID 104162680
Filename F30114A_10
Injected By MRO
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/23/2002
ICAL Date 11/25/2002 Received 01/06/2003
CCal Filename(s) F30114A_01 &F30114A_14 Extracted 01/09/2003
Method Blank ID BLANK-2640 Analyzed 01/14/2003 15:34
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0025 A 2,3,7,8-TCDF-13C 2.00 75
Total TCDF ND 0.0020 2,3,7,8-TCDD-13C 2.00 85
1,2,3,7,8-PeCDF-13C 2.00 78
2,3,7,8-TCDD ND 0.0034 A 2,3,4,7,8-PeCDF-13C 2.00 73
Total TCDD 0.0073 0.0020 J 1,2,3,7,8-PeCDD-13C 2.00 83
1,2,3,4,7,8-HxCDF-13C 2.00 75
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 82
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 85
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 79
1,2,3,4,7,8-HxCDD-13C 2.00 90
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 85
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 85
1,2,3,4,7,8,9-HpCDF-13C 2.00 88
j 1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 89
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 94
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2.3.7.8-TCDD-37CI4 0.20 76
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000046 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.0460 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-subslituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1067456