NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan December 23, 2002
Respirable Particulate Sampling Page 2
P.S. 234M ATCProiectNo. 15-19125-0279
The table lists target guideline for the parameter that ATC evaluated during this
investigation. Meeting the listed value does not assure that acceptable indoor air quality
will be achieved at all times.
TARGET GUIDELINE FOR INDOOR AIR QUALITY PARAMETER
EVALUATED
ssssa 65 micrograms per cubic
Respirable meter of air (gg/nP) 24-hour USEPA NPAAQS
Particulates (PMjs) average________________
40 micrograms per cubic USEPA recommendation for
meter of air (gg/m') 24-hour children and sensitive
average individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
RESULTS
ATC collected one (1) 24-hour gravimetric sample in the Main Lobby. The analytical
laboratory report is provided in the attachment.
The 24-hour average concentration of PM, 5 was 16.7 ug/m’ which is below both the EPA
NPAAQS for PM, 5 of 65 ug/n? and the EPA recommended level of 40 ug/m'.
It is our pleasure to provide these indoor air consultative services to the New York City
Department of Education. If you have any questions about this report, please call (212)
353-8280, extension 212.
Sincerely,
/I TC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager,
Industrial Hygiene Division
Attachment