[ Prepared Exclusively For: PEDNEAULTASSOCIATES, INC. 1615 NINTH AVENUE, BOX 205. BOHEMIA, N.Y. 11716 NYCDEP-Emergency Response & Tech Assmt. 96-05 Horace Harding Expressway LAB#: 01110050 Corona NY 11368 PROJECT ID WORLD TRADE CENTER-5 Boro Sampling (718) 595-4650 MATRIX: AIR\GAS

I m,p-Xylene 1.19 ppb v/v 0.1785 - USEPATO-15 11/3/01 Styrene ND ppb v/v 0.0896 USEPATO-15 11/3/01 1,1,2,2-Tetrachloroethane ND ppb v/v 0.1471 USEPATO-15 11/3/01 o-Xylene 0.40 ppb v/v 0.0111 USEPATO-15 11/3/01 1,3,5-Trimethylbenzene 0.13 ppb v/v 0.0757 USEPATO-15 11/3/01 1,2,4-Trimethylbenzene 0.41 ppb v/v 0.1511 USEPATO-15 11/3/01 1,3-Dichlorobenzene ND ppb v/v 0.1564 USEPATO-15 11/3/01 1,4-Dichlorobenzene ND ppb v/v 0.169 USEPATO-15 11/3/01 1.2-Dichlorobenzene ND ppb v/v 0.2014 USEPATO-15 11/3/01 1,2,4-T richlorobenzene ND ppbv/v 0.1785 USEPATO-15 11/3/01 Hexachloro-1.3-Butadiene ND ppb v/v 0.1976 USEPATO-15 11/3/01 Tentatively Identified Compounds USEPATO-15 11/3/01 2-Methyl butane 1.15 ppb v/v USEPATO-15 11/3/01

John Pedneault Page 8 of 16 ND=RESULT IS EQUAL TO OR LESS THAN MDL Lab Director NYS EIJ\P #10224 NR=NON REPORTABLE RESULTS MWBE #46075

CITY_21MC100_003071527

NYC-WTC_000334274

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000334274Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →