NYC-WTC_000333182
Lab results for ambient/indoor sampling at Greenwich & Chambers and other Broadway sites.
1 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗Asbestos air sampling table for WTC area with PCM results and LOD/LOQ data.
NYC-WTC_000332422–000332424OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
DATE: 09/20/01
WORLD TRADE CENTER ASBESTOS AIR SAMPLING TABLE Date? . -SampleID V^ipLoeatlon{ • Duration Sample PCM PCM Results Results Sampled - ‘ AMBIENT/ Sampled Volume LOD LOQ PCM TEM ..•■ul!. INDOOR (Mlns) (liters) (I7mm2) (Pcc) (f/cc) (struc./mm2) 09/19/01 I0919/A307002 N.END AVE & PARK PL WEST AMBIENT 45 675 0.05 09/19/01 I0919/A307003 RIVER TERRACE & VESEY ST AMBIENT 45 675 0.012 09/19/01 1O9I9/A3O7004 SOUTH END AVENUE & ALBANY ST AMBIENT 45 675 0.013 09/19/01 10919/A307005 RECTOR PL BY THE PARK AMBIENT 45 675 0.007 <0.007 09/19/01 302/005 THIRD PL/BATTERY PL WATERSIDE AMBIENT 45 675 0.007 <0.007 09/19/01 302/002 RIVER TERRACE/CHAMBERS ST AMgiciuT 675 0.012 09/19/01 302/003 RIVER TERRACE / PARK PL WEST AMBIENT 45 675 0.007 <0.007 09/19/01 302/004 W. THOMAS ST WATERSIDE AMBIENT 45 675 0.007 <0.007
o
o m
o 20 DO
>
i c □0 1"° o PG 3 OF 3 WTC2 WITH PRINTING FORMAT. 123 o o o Cd 05 CD 00 C75
NYC-WTC_000332424
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000333182
Lab results for ambient/indoor sampling at Greenwich & Chambers and other Broadway sites.
1 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333185
Asbestos air sample table with PCM/TEM results for WTC area, 9/12/01.
1 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307820
Laboratory table of asbestos fiber measurements from ambient air near WTC sites.
1 shared non-person entities · 1 shared topics · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361872
Ambient air PCM readings at WTC sites near Wall Street area.
1 shared non-person entities · 1 shared topics · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308187
World Trade Center air monitoring table listing asbestos fiber and related results by location.
1 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308179
World Trade Center air monitoring table listing fiber and asbestos data for multiple sites.
1 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196135
Table of ambient air fiber concentrations measured at various street intersections in early September 2001.
1 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361869
Indoor ambient fiber and asbestos readings at WTC sites.
1 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361863
Fiber and asbestos measurements at WTC ambient indoor sites.
1 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361891
Air monitoring table listing fiber/ambient results for perimeter locations around WTC.
1 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000203343
Table listing ambient air fiber counts and sampling parameters from perimeter locations in September.
1 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161628
Document discussing limitations of ASTM D5755-95 and D6480-99 for asbestos fiber sampling and lack of safety standards.
1 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000333182
Lab results for ambient/indoor sampling at Greenwich & Chambers and other Broadway sites.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000333185
Asbestos air sample table with PCM/TEM results for WTC area, 9/12/01.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000196135
Table of ambient air fiber concentrations measured at various street intersections in early September 2001.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308187
World Trade Center air monitoring table listing asbestos fiber and related results by location.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000361863
Fiber and asbestos measurements at WTC ambient indoor sites.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000308179
World Trade Center air monitoring table listing fiber and asbestos data for multiple sites.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000333182
Lab results for ambient/indoor sampling at Greenwich & Chambers and other Broadway sites.
Similar indexed content
NYC-WTC_000333185
Asbestos air sample table with PCM/TEM results for WTC area, 9/12/01.
Similar indexed content
NYC-WTC_000161628
Document discussing limitations of ASTM D5755-95 and D6480-99 for asbestos fiber sampling and lack of safety standards.
Similar indexed content
NYC-WTC_000307820
Laboratory table of asbestos fiber measurements from ambient air near WTC sites.
Similar indexed content
NYC-WTC_000361872
Ambient air PCM readings at WTC sites near Wall Street area.
Similar indexed content