Bulk, air, TEM, TEM–PCM methodologies, asbestos testing

Machine-extracted title · confidence 45%

décrit sampling frameworks: bulk, PCM, TEM, TEM/PCM; limits and interpretation.

NYC-WTC_000332265–000332267
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FACTS Fiber- a particle with a length that is three or more times its diameter. In a moving air stream fibers tend to align their length parallel to the diiection of rhe flow.

Panicle sizes less than 50 um are invisible.

Dust is defined as particulates less than 10 in diameter ????

In general particles greater than lOgm in greatest dimensions (diameter or length) do not enter the lung, they are collected by the nasal passage or tipper respiratory system.

Prolonged inhalation of asbestos fibers greater than 5 pin long may result in Asbestosis.

AHERA - Asbestos Hazard Emergency Response Act TEM - Transmission Microscopy - 40 CFR Part 763 25nini filter, pore size 0,4nm--polycarbonate filter Fiber Size > 0.5 pin & aspect ratio of 3:1 < 4> t k... PCM - Phase Contrast Microscopy NIOSH7400 Fibers measured, quick results 25 mm filter (385 sq, mm), pore size O.fyns -mixed cellulose ester Fiber Size > 5pm & aspect Ratio 5:1 OSHA-0.5-2.5Vmm £3. 2^5

Recommended Volume - 1200 to 1800 liters (less than 3800 liters) Max flow rate of 101/inin is recommended.

PEL 0.1 flee 8hrs TWA

Limit of Detection - The limit of detection is the smallest observed concentration that is unlikely to be due entirely to contamination.

Limit of Quantification - The limit of quantification is the minimum measured concentration that achieves a predetermined level of precision

Fibers shorter than 5 to 10 m do not cause diffuse plumonary fibrosis

Fibers more than 3m thick do not penetrate into alyeolated regions of the lung.

HEPA - High Efficiency Particulate Air filteration -99.97% 0.3 um ULP.A- Ultra-Low Pariculate (penetration) Air Filter - 99.999% of paricuiates down to 0.012 pm Electrostatic Process removes dust, dirt to 97% of 0.01 pm - no replacement bags

T v-a iKi3 11 P

•y-

I?!

CITY_21MC100_0 03070255

NYC-WTC_000332266

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000332266Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000455321

DOH letter explaining asbestos test results in lower Manhattan residences.

Similar indexed content

Compare copies and versions →