Asbestos Air Sampling, NYC Emergency Response

Machine-extracted title · confidence 55%

Air sampling results at NYC ER site for asbestos, with PCM and TEM notes.

NYC-WTC_000332138–000332142
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z o to z ■p

I o NYC Emergency Response Asbestos Air Sampling Results NYC ER/NJ DEP c o' ■o "□ o o q. o 03 Ca3 Ca3 Date Sampling Sample PCM by NIOSH 7400 TEM (AHERA) ro O 4^ Sampled Sample No. Location Volume Matrix f/mm^ f/cc 0.5p - 5p I 5p S/mm’ S~f/cc* o o S(#) c 3 10/14/01 02011 Liberty Park 480 Air <7.0 <0.006 0 0 <6.15 <0.0049 o Z5 10/14/01 02012 CITGO Terminal 480 Air <7.0 <0.006 0 0 <6 15 <0.0048 10/14/01 02013 FMC Terminal 480 Air <7.0 <0.006 0 0 <6.15 <0.0049 10/14/01 02014 Shell Terminal 480 Air <7.0 <0.006 0 0 <6.15 <0.0049 coc#04193

PCM: Phase Contrast Microscopy by NIOSH 7400 TEM: Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA). Sample volume is below recommended limit of the method. ‘Structure (S) roughly equivalent to Fiber (f) Standard criteria; EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM). 70 S/mm^ Volume 1200 L. for 25 mm filter (TEM)

Period in which samples were collected and retrived Sampling Location Sampling Times Liberty Park 1330 (10/14/01) - 2130 (10/14/01) CITGO Terminal 1415 (10/14/01) - 2215 (10/14/01) ERT; 10/16/01 09:50 AM FMC Terminal 1440 (10/14/01) - 2240 (10/14/01) Shell Terminal 1500 (10/14/01) - 2300 (10/14/01)

Q A kJ ’tQ

I o o DEP-10-14-01 o 4^ O CO CO cn

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000332141Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Lab report, NYC DEP · page 1

NYC-WTC_000368926

NYC Emergency Response; Asbestos Air Sampling Results NYC ER/NJ DEP

Similarity score 0.998 (not a probability)

machine-extracted · confidence unavailable · Check page ↗
Lab report, NYC DEP · page 1

NYC-WTC_000368905

Laboratory report from NYC Department of Environmental Protection; content not readable.

Similarity score 0.996 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →