NYC 9/11 Public Portal Document
Attn: Benjamin Sallemi Received: 10/9/02 1:00:00 PM
ATC Associates Inc. ATC Group#; 8950
104 East 25th Street Analysis Date: 10'13/02
New York NY 10010
Fax; {212) 353-3599 Phone: (212) 353-8280
Project: DEP Clean-up ATC Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area iSon Asbestos # Structures Sensitivity Concentration
Sample Volume Analyzed Asb Type(s) O.Sfi-5 5fi (S/ccJ (S/mm^) (S/cc) Notes
A2N 46 3600.00 0.1236 2 NoneDetected 0 0 0.0009 <8.09 <0.0009 Gypsum ■ 1 Structures. Glass -1 Structures
8950 -44
A 2N 47 3600.00 0.1236 3 NoneDetected 0 0 0.0009 <8.09 <0.0009 Cellulose -1 Structures. Gypsum - 2 Structures
8950 -45
A 2N 48 3600.00 0.1236 9 CHRYSOTILE T 0 0.0009 16.18 0.0017 Cellulose - 6 Structures. Gypsum - 3 Structures
8950 -46
A 2 49 3600.00 0.1236 I NoneDetected 0 0 0.0009 <8.09 <0.0009 Gypsum -1 Structures
8950 -47
A 1 50 3600.00 0.1236 1 NoneDetected 0 0 0.0009 <8.09 <0.0009 Cellulose -1 Structures
S950 -48
MARK PEYSAKHOV MICHAEL A. GORYCKl, Ph.D,
Analvzed bv: Apofoved by:
Z',
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This repon may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This reports' relates only to the samples reported above. Quality control data 'including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
Sunday, October 13, 2002 Page 6 of 6