NYC-WTC_000348491
Chain-of-custody outlining debris removal and interior cleaning by abatement contractor.
16 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Monitoring contractor requirements for on-site asbestos air sampling and clearance measurements.
NYC-WTC_000330742–000330746OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Air Sampling Technicians Air monitoring technicians must posses valid NYS Asbestos Project Sampling Technician (APST) certificates. Technicians must have performed air sampling for at least 6 months. At a minimum at least 5 Air Sampling Technicians must be assigned to this project. A single individual with Asbestos Project Monitor and Asbestos Project Sampling Technician certification shall not perform the fhnetions of both Monitor and Teclmician during this project.
Wipe Sampling Technicians Wipe sampling technicians must have 1-year experience in wipe sampling Tor a variety ot' contaminants and have received state certified training in dust sampling. At a minimum at leasfT Wipe Sampling Teehnicians must be assigned to this project.
Equipment \ Sampling equipment must be in sufficient quantity to provide the amount and type of samples required for this project. At a minimum the following equipment are required: air-sampling pumps with flow rate capacities of 2 to 10 liters per minute, tripods, rotometers, sample cassettes with mixed cellulose ester filters having pore size of 0.8pm, micro vacuum, disposable porous cellulosic towellettes moistened with wetting agent and solvent-wetted sampling agent. / ~ \ Analytical Laboratory / The environmental laboratory niitst be certified by the New York State Department of Health. ''' Certification for all the analytes specified herein must have been maintained for at least six (6) consecutive proficiency testing rounds. the laboratory must possess a gas chromatograph equipped with a capillary colunm and high-resolution mass spectrometer for analyzing dioxin and inductively coupled plasma for total metals. Cold Vapor Method apparatus shall be used for mercury analysis.
Proof of qualifications must be presented to the NYCDEP prior to commencement of work. The NYCDEP reserves the right to disqualify any individual(s) from work on this project for non-comphance with these specifications or the requirements of applicable rules and regulations.
Specifications
It is anticipated that the work will be completed within three (3) weeks.
Sampling and Analytical Procedures for Lead, PAHs, Dioxin, Fibrous Glass, Silica, and Mercury
1. Sampling for lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.
2. Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment.
2 of 5
CITY_21MC100_003068772
NYC-WTC_000330743
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000348491
Chain-of-custody outlining debris removal and interior cleaning by abatement contractor.
16 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000206792
Contract scope defining requirements for licensed abatement contractors to clean debris and monitor asbestos air sampling at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220321
DEP Bureau document defining scope for environmental sampling and asbestos air monitoring during interior cleaning at 125 Cedar Street.
16 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281926
Proposed on-site asbestos cleaning oversight and air monitoring requirements.
16 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281921
Contractor and monitoring requirements for asbestos cleaning at 125 Cedar Street.
16 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441311
Scope of work for asbestos sampling and air monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000252321
Chain of custody/SC for 125 Cedar Street cleaning and asbestos monitoring scope.
16 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444042
Chain-of-custody scope of work for asbestos air monitoring and debris cleanup at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434571
Duplicate scope of work for interior cleaning and asbestos monitoring at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435224
Scope for on-site asbestos air monitoring during interior cleaning at 125 Cedar Street.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445849
New York DEP scope-of-work document for 125 Cedar Street remediation.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153557
Document defining the scope for a monitoring contractor to oversee cleaning and conduct air sampling for various contaminants.
15 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000348491
Chain-of-custody outlining debris removal and interior cleaning by abatement contractor.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153557
Document defining the scope for a monitoring contractor to oversee cleaning and conduct air sampling for various contaminants.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000284068
DEP scope of work for asbestos abatement monitoring and contractor oversight at 125 Cedar Street.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430690
Follow-up scope for environmental sampling and asbestos monitoring at 125 Cedar Street.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444042
Chain-of-custody scope of work for asbestos air monitoring and debris cleanup at 125 Cedar Street.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441728
Scope of work for asbestos abatement monitoring and clearance sampling.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000348491
Chain-of-custody outlining debris removal and interior cleaning by abatement contractor.
Similar indexed content
NYC-WTC_000206792
Contract scope defining requirements for licensed abatement contractors to clean debris and monitor asbestos air sampling at 125 Cedar Street.
Similar indexed content
NYC-WTC_000220321
DEP Bureau document defining scope for environmental sampling and asbestos air monitoring during interior cleaning at 125 Cedar Street.
Similar indexed content
NYC-WTC_000281926
Proposed on-site asbestos cleaning oversight and air monitoring requirements.
Similar indexed content
NYC-WTC_000281921
Contractor and monitoring requirements for asbestos cleaning at 125 Cedar Street.
Similar indexed content