OSHA sampling results summary, 11/8, D&C Dept

Machine-extracted title · confidence 25%

Asbestos sampling results summary with counts and analyses for rubble pile area.

NYC-WTC_000330527–000330528
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SO2 personal and area results were found to be below OSRA. limits.

Metals: As of 11/3/01 OSHA has taken 368 air samples to monitor worker exposures to dusts, fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium, cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury'. Results from these samples are generally well below the applicable OSRk limits. However, torch cutting and burning structural steel at the rubble pile have resulted in instances of overexposures as follows: copper (6); iron oxide (8); lead (5); and cadmium (2). Accordingly, OSHA is recommending that workers engaged in these operations wear appropriate respiratory' protection.

Ionizing Radiation: A surx'ey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with particular attention to alpha radiation. Preliminary results show no elevated levels. Dioxins: The single sample taken by OSHA and analyzed by the EPA, representing exposure on the pile, showed elevated levels of dioxins. These levels were substantially higher than background levels but comparable to levels found by the EPA on the rubble pile. The dioxins found here are emitted from the on­ going rubble fire. OSHA does not have a worker standard for dioxins. Dioxins are considered collectively as suspect human carcinogens. Some of the individual compounds are considered to be known human carcinogens. OSHA has taken additional samples which have all been forwarded for analysis. OSHA is coordinating with EPA, and Salt Lake City Anal>^ical Laboratory to more fully characterize exposure and risk around the rubble pile.

Polynucleated Aromatic Hydrocarbons: OSHA identified several elevated samples, three of which reached or exceeded OSHA’s coal tar pitch volatile PEL of .2mg/m^' These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to strongly recommend the use of respiratory protection when working on the rubble pile.

Freon R-22, Hydrogen Fluoride & Phosgene: OSHA has conducted sampling for Freon R-22 (chlorodiflouromethane). Sample results received reveal non-detectable airborne levels. In response to information about exposure to the decomposition by-products of Freon R-22 used in the air conditioning systems of WTC towers, sampling for hydrofluoric acid (HF) had been conducted. Results of the HF revealed non-detectable levels. Sample results for phosgene show non-detectable levels.

Page 2 of 2

CITY_21MC100_006754685

NYC-WTC_000330528

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000330528Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →