NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗TEM results summary for Eduction Dept project at H.S. basement and floors 1-6, Oct 10, 2001.
NYC-WTC_000329991–000330011OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/10/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763;, Vol. 52, No. 210, October 30, 1987
Semple CdentifLcatixon Tmalyais Parameters
Froject/Sita: Murry Bergtraum H.5., 411 Pearl St., NY, NY TEM Sample No.: 5650 - 6Q713 Basement & Floors 1-6 Date Received: 10/09/01 Grid Openings Analyzed: 4
?ro:ect Sample No.: MBHS-B>6-10/9-21 Average Grid Opening: 106.00 um
Air Volume : 15.36 Liters Total Area Analyzed: 0.04 50 rnm2
P.ilter Type; MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:22^2,^S2hTim2 Effective Area: 385 mm2 0.QQ47 g/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total - Struct Filter Air Fibers Bundles Clusters Struct. Struct >=5uni Struct/mm2 Strucc/cc ncm/mS
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0
Nion-Asbestos 0 0 0 0 0 0.0 0 0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The e.scimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003274218
NYC-WTC_000330009
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293691
TEM fiber analysis and diffraction/EDS report for a school site, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340268
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330178
TEM asbestos analysis at HS for Economics & Finance, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340298
TEM analysis with SAED/EDS for AHERA method, project site at H.S., 10/04/01
5 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340260
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330184
TEM asbestos analysis with SAED/EDS for HS site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340263
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330161
TEM analysis report for HS for Economics & Finance project; includes SAED/EDS.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340257
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330205
TEM asbestos analysis with SAED/EDS for NYC DOE project, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294146
TEM analysis report for Stuyvesant HS, including air volume and sample diameter.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270586
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330162
TEM report with project/site details and sample identifiers.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330178
TEM asbestos analysis at HS for Economics & Finance, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330195
TEM identification by SAED/EDS for project site in NYC, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM asbestos analysis by SAED/EDS for air samples at New Stuyvesant High School.
Similar indexed content
NYC-WTC_000293691
TEM fiber analysis and diffraction/EDS report for a school site, Oct 2001.
Similar indexed content
NYC-WTC_000270116
Asbestos fiber analysis by TEM with SAED/EDS for Stuyvesant HS, Oct 2001.
Similar indexed content
NYC-WTC_000340268
Asbestos TEM analysis (SAED/EDS) for HS project site, Oct 2001.
Similar indexed content
NYC-WTC_000330178
TEM asbestos analysis at HS for Economics & Finance, Oct 2001.