ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/18/01 ASBESTOS FIBER ANALYSIS BY TRAFISMISSION ELECTRON MICROSCOPY (TEM) With riser Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy [EDS) Method; AHE.RA Final Rule, EPA Federal .Rscister (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Proj ect./Site: Man. Academy of Tech., 122 Henry St., NY, NY TEM Samole No.: 5718 61599 3rd Floor Date Received: 10/18,/QI Grid Openings Analyzed:__ 4

Project Sample No. : Average Grid Opening: L06.0O urn

Ail Volume: 1890 Liters Total Area Analyzed

Filter Type: MCD 25 mm diam., Pore Size; Q,4S urn Analytical Sensitivity: 22.2 3/mm2 affective Area: 385 mm2 0.004S s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct, Filter Air Fibers Bundles Clusters Ctnirt- :5uni Struct,^inm2 Struct/cd nqm/mS

Chrysotile .^isbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asoestos {includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003274158

NYC-WTC_000329960

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329960Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →