Mr. Bernard P. Orlan October 8, 2002
Respirable Particulate Sampling Page 2
P.S. 89M ATC Project No. 15-19125-0297
The table lists target guideline for the parameter that ATC evaluated during this
investigation. Meeting the listed value does not assure that acceptable indoor air quality
will be achieved at all times.
TARGET GUIDELINE FOR INDOOR AIR QUALITY PARAMETER
EVALUATED
PARAMETER 1 T AGENCY OR
_____________________ O Rf1AMZA1 ION
65 micro grams per cubic
Respirable meter of air (pg/mQ 24-hour USEPA NPAAQS
Particulates ,(PM2 5) average
40 micro grams per cubic. USEPA recommendation for
meter of air (pg/mQ 24-hour children and sensitive
average individuals
USEPA = United States Environmental Protection Agency
a
NPAAQS = National Primary Ambient-Air Quality Standard
RESULTS
ATC collected one (1) 24-hour gravimetric sample in the V‘ Floor Hallway by the
cafeteria. The analytical laboratory report is provided in the attachment.
The 24-hour average concentration of PMj 5 was 7.64 ug/m’, which is below both the
EPA NPAAQS for PM, 5 of 65 ug/m^ and the EPA recommended level of 40 ug/m\
It is our pleasure to provide these indoor air consultative services to the New York City
Department of Education. If you have any questions about this report, please call (212)
353-8280, extension 212.
Sincerely,
ATC ASSOCIATES INC.
James R. Cohn, CIH, CSP
Regional Manager,
Industrial Hygiene Division