NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 2, 2003
Respirable Particulate Sampling Page 2
P.S. 234M ATC Project No. 15-19125-0279
The table lists target guideline for the parameter that ATC evaluated during this
investigation. Meeting the listed value does not assure that acceptable indoor air quality
will be achieved at all times.
TARGET GUIDELINE FOR INDOOR AIR QUALITY PARAMETER
EVALUATED
PAR.4METER TARGET LEVEL AGENCY OR
ORGANIZATION
65 micrograms per cubic
Respirable meter of air (pg/m’) 24-hour USEPA NPAAQS
Particulates (PM;,) average________________
40 micrograms per cubic USEPA recommendation for
meter of air (pg/m’) 24-hour children and sensitive
average individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
RESULTS
ATC collected one (1) 24-hour gravimetric sample in the Main Lobby. The analytical
laboratory report is provided in the attachment.
The 24-hour average concentration of PM, , was 5.56 ug/m^ which is below both the EPA
NPAAQS for PM2 5 of 65 ug/m^ and the EPA recommended level of 40 ug/m\
It is our pleasure to provide these indoor air consultative services to the New York City
Department of Education. If you have any questions about this report, please call (212)
353-8280, extension 212.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager,
Industrial Hygiene Division
Attachment
CITY_21MC1OO_OO3272933
NYC-WTC_000329115
OCR can misread numbers and units. Confirm readings against the page image before using them.