Pace Analytical Services, Inc. 1700 Elm Street - Suite 200 Minneapolis. MN 55414

we Analytical_________ Method 8290 Analysis Results Tai: 612-607-1700

Client - ATC ASSOCIATES Client’s Sample ID ATC-0820-234M-DX-2 Lab Sample ID 103792396 Filename F20926B_13 Injected By BAL Total Amount Extracted 1.00 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 08/20/2002 ICAL Date 09/26/2002 Received 08/22/2002 CCal Filename(s) F20926B_02 & F20926B_16 Extracted 09/17/2002 Method Blank ID BLANK-2163 Analyzed 09/27/2002 06:52 Native Cone EMPC LRL Internal ng’s Percent Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery 2,3,7,8-TCDF ND 0.0054 A 2,3,7.8-TCDF-13C 2.00 36 P Total TCDF 0.0097 0.0020 J 2,3,7,8-TCDD-13C 2.00 37 P 1,2,3,7,8-PeCDF-13C 2.00 41 2,3,7,8-TCDD ND 0.0061 A 2,3.4,7,8-PeCDF-13C 2.00 43 Total TCDD 0.0300 0.0020 1,2,3,7,8-PeCDD-13C 2.00 42 1,2,3,4,7,8-HxCDF-13C 2.00 42 1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6.7,8-HxCDF-13C 2.00 40 2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 40 Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 41 1,2,3,4,7,8-HxCDD-13C 2.00 49 1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 35 P Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 34 P 1,2.3,4,7,8,9-HpCDF-13C 2.00 31 P 1.2,3,4,7,8-HxCDF ND 0.0100 1.2,3,4,6,7,8-HpCDD-13C 2.00 33 P 1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 26 P 2,3,4,6,7,8-HxCDF ND 0.0100 1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA

1,2.3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 40 1,2,3,6,7,8-HxCDD ND 0.0100 1,2,3,7,8,9-HxCDD ND 0.0100 Total HxCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD 1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00031 ng/m2 Total HpCDF ND 0.0100 (Using ITE Factors) 1,2,3,4,6,7,8-HpCDD 0.0150 0.0100 J Total HpCDD 0.0330 0.0100 J OCDF ND 0.0200 OCDD 0.1600 0.0200 LRL = Lower Reporting Limit Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference EMPC = Estimated Maximum Possible Concentration E = PCDE Interference A = Detection Limit based on signal-to-noise measurement S = Saturated signal J = Concentration detected is below the calibration range ND = Not Detected B = Less than 10 times higher than method blank level NA = Not Applicable P = Recovery outside of target range NC = Not Calculated Nn = Value obtained from additional analysis * = See Discussion Report No.... 1061639

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CIT Y_ 2IMCIOO^777719 NYC-WTC_000328942

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000328942Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →