Mr. Bernard P. Orlan September 11, 2002
Air Sampling for Metals Page 2
DeSoto School (P.S. 130M) ATC Project No. 15-19125-0345
The established regulatory values for metals are intended for industrial workplace
exposures and are not generally applicable to office/school settings. There are no
standards for these metals in indoor air in non-indiistrial situations.
Results
Aluminum and chromium were detected in all of the samples obtained (including the
blank). Blank-correcting the samples lowers the Al and Cr concentrations to below the
limits of detection for the analyses. Copper was detected only in one sample (ID # ATC-
0826-130M-M1 ) in the Main Lobby with concentration of 0.556 ug/m^.
The Environmental Protection Agency (EPA) has set a screening level for hexavalent
chromium in air of 0.6 ug/m^, this assumes a continuous exposure for one year. The
samples here were analyzed for total chromium (trivalent and hexavalent). The
concentrations are well below the EPA level.
The EPA has set no screening levels for Al or Cu in ambient air.
•i
ATC appreciates the opportunity to provide this indoor air quality service to the DOE.
Please call me at (212) 353-8280 extension 298 if you have any questions.
Sincerely,
ATC Associates, Inc.
Reviewed by:
Wagdi Abdelshahid James R. Cohn, CIH, CSP
Industrial Hygienist Regional Manager
Industrial Hygiene Division