Mr. Bernard P. Orlan August 29, 2002 Indoor Air Quality Assessment Page 3 P.S.2M ATCProiectNo. 15-19125-0341
Real-Time Environmental Measurements
ATC collected fifty (50) sets of real-time environmental measurements consisting of forty-eight (48) in the school building and two (2) outdoors. All floors of the school were surveyed. Field data sheets are found in the Attachment. Readings were collected during school hours. The results are described below.
Temperature
Indoor dry bulb temperature measurements ranged from 81.9 to 87.1 °F. All indoor measurements were above the range of 73 to 79 °F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements were 81.6 and 82.2 °F collected before and after the indoor samples.
Relative Humidity
The relative humidity indoors ranged from 41.6 percent to 62.4 percent. Four (4) of the indoor measurements for relative humidity were slightly above the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements were 61.6 and 61.8 percent collected before and after the indoor samples.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 642 ppm to 1210 ppm. All indoor measurement for COn were below the ASHRAE Standard 62-2001 recommended maximum concentration of <700 ppm above the background level. The average outdoor (background) CO2 concentration was 559 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1259 ppm (background level •+ 700 ppm). Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors ranged from 2 ppm to 3 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The average outdoor CO concentrations was 2 ppm.
Respirable Particulates (PM2^5)
Respirable particulate concentrations* indoors ranged between 33 pg/m^ to 49 pg/m^. All indoor measurements collected for PM2.5 were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Thirt}' one (31) of the forty-eight (48) instantaneous indoor readings were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children. The two outdoor respirable particulate concentrations were 58 pg/m^ and 57 pg/m^ with an average of 57.5 pg/m^. Both outdoor measurements for PM2.5 were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter.
CITY_21MC100_011276586
NYC-WTC_000328673
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000207966
Report detailing indoor air quality measurements collected at a school location on August 23, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309368
Memo noting indoor air quality measurements at PS 2M, Aug 2002.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309350
Indoor air quality measurements at PS 2M, Aug 23, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309359
Memo regarding IAQ measurements at PS 2M, Aug 23, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000316861
ATC Associates provided IAQ measurements taken at the referenced NYC Department of Education school on August 23, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000316852
ATC indoor air quality measurements for P.S. 2M, Aug 23, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239336
ATC Associates report detailing indoor air quality measurements collected at Murray High School on September 9, 2002.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239406
Report on indoor air quality measurements conducted at a New York City high school on September 9, 2002.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000207989
Letter providing indoor air quality measurement results from August 23, 2002, at P.S. 2M to verify acceptable air conditions.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351250
ATC report on IAQ measurements at the school to verify acceptable conditions.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239194
Report on indoor air quality measurements collected at Murray High School on September 9, 2002, to verify acceptable air conditions.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239267
Report on indoor air quality measurements taken at Murray High School to verify acceptable air conditions.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000309359
Memo regarding IAQ measurements at PS 2M, Aug 23, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000310159
ATC indoor air quality measurements at a DOE school for August 27, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309350
Indoor air quality measurements at PS 2M, Aug 23, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000316861
ATC Associates provided IAQ measurements taken at the referenced NYC Department of Education school on August 23, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309368
Memo noting indoor air quality measurements at PS 2M, Aug 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000207966
Report detailing indoor air quality measurements collected at a school location on August 23, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000207966
Report detailing indoor air quality measurements collected at a school location on August 23, 2002.
Similar indexed content
NYC-WTC_000309368
Memo noting indoor air quality measurements at PS 2M, Aug 2002.
Similar indexed content
NYC-WTC_000309350
Indoor air quality measurements at PS 2M, Aug 23, 2002.
Similar indexed content
NYC-WTC_000309359
Memo regarding IAQ measurements at PS 2M, Aug 23, 2002.
Similar indexed content
NYC-WTC_000316861
ATC Associates provided IAQ measurements taken at the referenced NYC Department of Education school on August 23, 2002.
Similar indexed content