NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan September 19, 2002
Respirable Particulate Sampling Page 2
Murray Bergtraum H.S. (M520) ATC Project No, 15-19125-0351
TABLE 1
TARGET GUIDELINE FOR INDOOR AIR QUALITY PARAMETER
EVALUATED
■■■I
PARAMETER
ii
w
■■■I
TARGET I EVEI,
_____________________ IM
ilBI
Si
■ ORGA?
65 micrograms per cubic
Respirable meter of air (pg/mQ 24-hour USEPA NPAAQS
Particulates (PM, ,-) average_________________
40 micrograms per cubic USEPA recommendation for
meter of air (pg/n?) 24-hour children and sensitive
average individuals
USEPA = United States Environmental Protection Agency
NPAAQS = National Primary Ambient-Air Quality Standard
RESULTS
ATC collected one (1) 24-hour gravimetric sample in the Main Lobby.
The 24-hour average concentration of PM2 5 was less than 3.47ug/m’ (below the limit of
detection) which is below both the EPA NPAAQS for P\L j of 65 ug/m^ and the EPA
recommended level of 40 ug/m\
It is our pleasure to provide these indoor air consultative services to the New York City
Department of Education. If you have any questions about this report, please call (212)
353-8280, extension 370 or 212.
Sincerely,
A TC ASSOCIA TES INC.
A
Reviewed by:
Tenzhr'Namgyal James R. Cohn, CIH, CSP
Industrial Hygienisi Regional Manager,
Industrial Hygiene Division
Attachment