NYC-WTC_000313720
ATC INDOOR AIR QUALITY report for PS/89M, detailing measurements and scope.
14 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗ATC reports IAQ measurements collected May 23, 2002 at PS 89M.
NYC-WTC_000328385–000328388OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan May 24, 2002 Indoor Air Quality Assessment Page 2 P. S. 89M ATC Project No. 15-19125-0297
EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications;
Ventilation for Acceptable Indoor’ Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide, to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.
TABLEI TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED .R Wil l ER I .\R(. III III ______ _J ■■1 Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (pg/m^) 24-hour average 40 pg/m^ 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter; 68-75°F at 50% RH Relative Humidity 30-60 % ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene .Association
CITY_21MC100_003272111
NYC-WTC_000328386
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000313720
ATC INDOOR AIR QUALITY report for PS/89M, detailing measurements and scope.
14 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369158
Indoor air quality measurements collected at P.S. 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313744
ATC IAQ report for PS/89M with measurements and scope.
14 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369869
INDOOR AIR QUALITY measurements at PS/IS89M for BOE evaluation, dated May 24, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313756
ATC IAQ measurements at PS/89M to assess air quality.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369893
Indoor air quality measurements collected at P.S. 89M for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369905
Indoor air quality measurements at P.S. 89M released May 30, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369765
ATC IAQ measurements at PS 89M for BOE, May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369917
Report of indoor air quality measurements at P.S. 89M for BOE, May 31, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370061
ATC reports indoor air quality measurements taken June 17, 2002 at PS 89M for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369170
Indoor air quality measurements for P.S. 89M in May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000313797
ATC report of IAQ measurements at PS/89M school building.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370025
ATC IAQ measurements conducted June 12, 2002 for BOE air quality evaluation.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370001
ATC IAQ measurements conducted June 10, 2002 for BOE air quality evaluation.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328393
ATC provides IAQ measurements collected May 28, 2002 for PS 89M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369869
INDOOR AIR QUALITY measurements at PS/IS89M for BOE evaluation, dated May 24, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000210984
Report of indoor air quality measurements conducted at P.S. 89M on May 22, 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000313720
ATC INDOOR AIR QUALITY report for PS/89M, detailing measurements and scope.
Similar indexed content
NYC-WTC_000369158
Indoor air quality measurements collected at P.S. 89M for BOE.
Similar indexed content
NYC-WTC_000313744
ATC IAQ report for PS/89M with measurements and scope.
Similar indexed content
NYC-WTC_000369869
INDOOR AIR QUALITY measurements at PS/IS89M for BOE evaluation, dated May 24, 2002.
Similar indexed content
NYC-WTC_000313756
ATC IAQ measurements at PS/89M to assess air quality.
Similar indexed content