Mr. Bernard P. Orlan April 9, 2002 Indoor Air Quality Assessment Page 3 P, S. 89M ATC Project No. 15-19125-0297
Real-Time Environmental measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 7;00 A.M. and concluded at approximately 11:15 A.M.
Temperature
Indoor dry bulb temperature measurements ranged from 69.5 °F to 75.7 °F. Nine (9) of the indoor measurements were above the range of 68 to 75°F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements ranged from 51.3 to 55.5 °F.
Relative Humidity
The relative humidity indoors ranged from 26.1 to 29.8 percent. All of the measurements were below the ASITRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 35.7 to 36.7 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 476 ppm to 698 ppm. None of the CO2 measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 398 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1098 ppm (backgroimd level +- 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 1 ppm for all readings.. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration was also 1 ppm for all collected readings.
Respirable Particulates (PM2/j)
Respirable particulate concentrations* indoors ranged between 8 pg/m^ to ngg/m^. All of the measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM2.5 concentration for the entire school building was approximately 11 pg/nP. The PM?.5 average concentration was below the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged from 24 to 27 gg/m^ with an average of 25 pg/m^.
CITY_21MC1OO_OO327168O
NYC-WTC_000328216
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000394376
Indoor air quality measurements at PS 89M for BOE; April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394388
April 2002 indoor air quality measurements at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400137
ATC IAQ report for PS 89M, March 4, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313428
IAQ measurements at PS 89M; BOE requested evaluation, April 8-12, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000394392
April 2002 indoor air quality measurements at PS 89M (series).
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313589
Indoor air quality measurements collected at PS 89M for BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220647
Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 8, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313667
ATC measurements for PS 89M on May 15, 2002, temperature and humidity.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392756
ATC report detailing indoor air quality measurements at the referenced school.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370049
ATC IAQ measurements conducted June 14, 2002 for BOE air quality evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000392864
ATC report of IAQ measurements at PS 89M requested by BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313439
IAQ report for P.S. 89M; measurements collected April 9-11, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000220647
Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 8, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000222470
ATC Associates letter submitting indoor air quality measurement results collected on April 15, 2002, at P.S. 89M for the NYC Board of Education.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400206
IAQ measurements report for PS 89M, March 13, 2002, ATC.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300615
ATC indoor air quality measurements at PS 150M prior to re-occupancy.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000194816
Cover letter for indoor air quality measurements collected at PS150M on February 15, 2002, submitted to the Board of Education.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375481
Indoor air quality measurements collected Feb 11, 2002 for PS 150M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000394376
Indoor air quality measurements at PS 89M for BOE; April 2002.
Similar indexed content
NYC-WTC_000394388
April 2002 indoor air quality measurements at P.S. 89M.
Similar indexed content
NYC-WTC_000400137
ATC IAQ report for PS 89M, March 4, 2002.
Similar indexed content
NYC-WTC_000313428
IAQ measurements at PS 89M; BOE requested evaluation, April 8-12, 2002.
Similar indexed content
NYC-WTC_000394392
April 2002 indoor air quality measurements at PS 89M (series).
Similar indexed content