NYC-WTC_000326910
Indoor air quality measurements reported for PS 89M; March 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC memo reporting IAQ measurements at a NYC BOE school (Feb 28, 2002).
NYC-WTC_000327491–000327494OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan February 28, 2002 Indoor Air Quality Assessment 1^ Page 2 P.S.89M ATC Project No. 15-19125-0297 ( sampling and analytical accuracy. The results of the sampling represent cohditi ons found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.
EVALUATION CRITRRTA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such a.s offices and schools. For the real-time data collected, ATG uses the commonly accepted guidelines cited m the following publications;
Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations {1993), American Industrial Hygiene Association (AIHA).
Table 1 lists target guidelines for the parameters that ATG evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times. A
7 : TABLE 1 ; TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAAIRTURS lA ALl ATLl) MFI ER MUiNCA OR ___ ; _ OR GWIZAIIOX MMMll Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm. ASHRAE 62 (adopted from (CO) 1 ) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PMg 5) of air (pg/m3) 24-hour average 40 pg/md 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer; 73-79"F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30 -60 % ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association
CITY_21MC1OO_OO3271O12
NYC-WTC_000327492
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000326910
Indoor air quality measurements reported for PS 89M; March 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326923
Indoor air quality measurements at PS 89M; March 27, 2002 report.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326893
Indoor air quality measurements collected at the referenced school, March 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326715
ATC indoor air quality measurements at PS 89M, March 1, 2002, for NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383724
Indoor air quality report for PS 89M; measurements taken Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326754
ATC IAQ measurements at PS 89M, March 6, 2002, per BOE request.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400153
Indoor air quality measurements report for PS 89M, March 6-7, 2002, ATC.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382671
ATC memo documenting IAQ evaluation scope at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375521
IAQ measurements at PS 150M prior to re-occupancy, March 12, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400149
IAQ measurements report for PS 89M, March 2002, ATC.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326936
Indoor air quality report for PS 89M; school evaluation requested by BOE.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274686
ATC IAQ evaluation report for P.S. 89M; Mar 4, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000326880
Report of IAQ measurements conducted at PS 89M for BOE evaluation, March 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294468
Indoor air quality measurements conducted at the referenced school in March 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315445
ATC IAQ measurements report for PS 234M, BOE requested, NYC.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314805
ATC IAQ measurements conducted March 20, 2002 for BOE at PS 234M.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371929
May 2002 IAQ measurement report for PS 234M, BOE.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326910
Indoor air quality measurements reported for PS 89M; March 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000326910
Indoor air quality measurements reported for PS 89M; March 2002.
Similar indexed content
NYC-WTC_000326923
Indoor air quality measurements at PS 89M; March 27, 2002 report.
Similar indexed content
NYC-WTC_000326893
Indoor air quality measurements collected at the referenced school, March 2002.
Similar indexed content
NYC-WTC_000326715
ATC indoor air quality measurements at PS 89M, March 1, 2002, for NYC BOE.
Similar indexed content
NYC-WTC_000383724
Indoor air quality report for PS 89M; measurements taken Feb 2002.
Similar indexed content